Cited 0 time in
Design of workpiece size measurement system using camera
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Seo, J.-Y. | - |
| dc.contributor.author | Kim, G.-S. | - |
| dc.date.accessioned | 2022-12-26T16:16:07Z | - |
| dc.date.available | 2022-12-26T16:16:07Z | - |
| dc.date.issued | 2019 | - |
| dc.identifier.issn | 1976-5622 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/10686 | - |
| dc.description.abstract | In this paper, the workpiece size measurement system is designed to measure the size (width and height) of a workpiece using the measurement system with a camera. The system consists of a body, a vertical camera movement mechanism, a horizontal camera focus adjustment mechanism, a horizontal illumination device, a vertical illumination device, an infrared sensor, and a control device. To improve the measurement accuracy, camera calibration and image rotation calibration were performed, and image processing was performed using a subpixel algorithm. As a result of measuring the width and height of the block gauges as a reference object using the workpiece size measurement system, the width measurement accuracy was ±0.0041 mm and the height measurement accuracy was ±0.0043 mm. Therefore, it is considered that the designed workpiece size measurement system can measure a workpiece with accuracy less than ± 0.01. ? ICROS 2019. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | Institute of Control, Robotics and Systems | - |
| dc.title | Design of workpiece size measurement system using camera | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5302/J.ICROS.2019.19.0102 | - |
| dc.identifier.scopusid | 2-s2.0-85073357312 | - |
| dc.identifier.bibliographicCitation | Journal of Institute of Control, Robotics and Systems, v.25, no.9, pp 818 - 826 | - |
| dc.citation.title | Journal of Institute of Control, Robotics and Systems | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 818 | - |
| dc.citation.endPage | 826 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002500811 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Camera calibration | - |
| dc.subject.keywordAuthor | Height measurement accuracy | - |
| dc.subject.keywordAuthor | Horizontal illumination device | - |
| dc.subject.keywordAuthor | Vertical camera movement mechanism | - |
| dc.subject.keywordAuthor | Workpiece size measurement system | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
