Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

계장용 볼 밸브 유량계수 Cv 측정에 관한 연구open accessA Study of the Measurement of the Flow Coefficient Cv of a Ball Valve for Instrumentation

Other Titles
A Study of the Measurement of the Flow Coefficient Cv of a Ball Valve for Instrumentation
Authors
강창원이중섭정세민이치우
Issue Date
2019
Publisher
한국기계가공학회
Keywords
Ball Valve(볼밸브); Flow Coefficient(유량계수); CFD(전산유체역학); Numerical Analysis(수치해석)
Citation
한국기계가공학회지, v.18, no.3, pp 103 - 108
Pages
6
Indexed
KCI
Journal Title
한국기계가공학회지
Volume
18
Number
3
Start Page
103
End Page
108
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/9791
DOI
10.14775/ksmpe.2019.18.3.103
ISSN
1598-6721
2288-0771
Abstract
The results of the measurement of the flow-rate coefficient (Cv-value) and the analysis of a small ball valve are summarized follows. The Cv-values of 1/2-, 3/4- and 1-inch ball valves were measured using a flow-rate measurement test. The manufacturer obtained the Cv-value using a theoretical calculation method. The new experimental measurement and analysis method yielded more reliable results. In addition, the Cv value obtained through numerical analysis was almost identical the value provided by the manufacturer, which was based on experimental results. A Study on Flow Analysis results are all similar appearances as the reliability of the results.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Chi Woo photo

Lee, Chi Woo
공과대학 (미래자동차공학과)
Read more

Altmetrics

Total Views & Downloads