PVC membrane-based portable ion analyzer for hydroponic and water monitoring

Authors
Kim, Hak-JinKim, Dong-WookKim, Won KyungCho, Woo-JaeKang, Chang Ik
Issue Date
Aug-2017
Publisher
Elsevier BV
Keywords
Ion-selective electrode; Two-point normalization; Nitrate; pH; Potassium
Citation
Computers and Electronics in Agriculture, v.140, pp 374 - 385
Pages
12
Indexed
SCIE
SCOPUS
Journal Title
Computers and Electronics in Agriculture
Volume
140
Start Page
374
End Page
385
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/77480
DOI
10.1016/j.compag.2017.06.015
ISSN
0168-1699
1872-7107
Abstract
Rapid on-site measurement of chemical ions in hydroponic and water solutions would allow efficient management of nutrients used for plant production as well as early monitoring of chemical pollutants. This paper reports the development of an embedded portable analyzer incorporated with a sensor array of polyvinyl chloride (PVC) membrane-based ion-selective electrodes (ISEs) to directly measure the concentrations of NO3, K, and H ions in hydroponic solutions and water. The developed ion analyzer consisted of an AVR microcontroller, five channels of sensor inputs, a 16-bit analog-to-digital converter, a 7-inch LCD touch panel, and SD memory card-based data storage. The use of a two-point normalization method consisting of sensitivity adjustment followed by offset compensation was effective in minimizing signal drifts resulting from a series of sample measurements while reducing variability in response among multiple ISEs during replicate measurements in practical manners. The sensitivity and predictive capability of the PVC membrane-based H ISEs, in conjunction with a three-point calibration method, were satisfactory, showing sub-Nernstian slopes of 51.9-56.1 mV/decade over a pH range of 4-10 (R-2 > 0.96) and providing results in close agreement with the results of a conventional pH meter (a nearly 1:1 regression slope and a y-intercept near 0). A response time of 50 s and a wide sensitivity range of 11884 mg L-1 measured with the prototype portable ion analyzer equipped with PVC membrane-based NO3 and K ISEs, each with a lifetime of 60 days, enabled direct analysis of hydroponic and water samples without the need to dilute samples. Strong linear relationships between the prototype ion analyzer and the standard instrument methods (R-2 > 0.97, slopes ranging from 0.89 to 1.24) were exhibited. (C) 2017 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Woo Jae photo

Cho, Woo Jae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE