Detailed Information

Cited 2 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patientsopen access

Authors
Yonghan ChaSangyeob LeeJi-Ho BaeYang Jae KangJi-Hoon BaekJoon Soon KangChan Ho ParkShin June KimJun-Il Yoo
Issue Date
Feb-2025
Publisher
대한정형외과학회
Keywords
Total hip arthroplasty; Hip fracture; Artificial intelligence; Gait analysis
Citation
Clinics in Orthopedic Surgery, v.17, no.1, pp 62 - 70
Pages
9
Indexed
SCIE
SCOPUS
KCI
Journal Title
Clinics in Orthopedic Surgery
Volume
17
Number
1
Start Page
62
End Page
70
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/75922
DOI
10.4055/cios24148
ISSN
2005-291x
2005-4408
Abstract
Background: This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures. Methods: A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively. Results: The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072). Conclusions: Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
Files in This Item
There are no files associated with this item.
Appears in
Collections
자연과학대학 > Division of Life Sciences > Journal Articles
의학계열 > 수의학과 > Journal Articles
의학계열 > 의학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Yang Jae photo

Kang, Yang Jae
자연과학대학 (생명과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE