Evaluation of input-output energy use in strawberry production in single-span double-layered greenhouses with different thermal-curtain positionsEvaluation of input-output energy use in strawberry production in single-span double-layered greenhouses with different thermal-curtain positions

Other Titles
Evaluation of input-output energy use in strawberry production in single-span double-layered greenhouses with different thermal-curtain positions
Authors
Timothy Denen Akpenpuun나욱호Qazeem Opeyemi OgunlowoAnis RabiuMisbaudeen Aderemi AdesanyaPrabhat DuttaEzatullah Zakir김현태이현우
Issue Date
Sep-2023
Publisher
충남대학교 농업과학연구소
Keywords
analysis; energy; input-output; productivity; ratios
Citation
Korean Journal of Agricultural Science, v.50, no.3, pp 395 - 406
Pages
12
Indexed
KCI
Journal Title
Korean Journal of Agricultural Science
Volume
50
Number
3
Start Page
395
End Page
406
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/68189
DOI
10.7744/kjoas.500309
ISSN
2466-2402
2466-2410
Abstract
The large amount of energy required for successful crop production is the main challenge in greenhouse cropping systems. As a response to this challenge a comprehensive evaluation of greenhouse energy consumption was carried out in two structurally similar single-span greenhouses with different thermal curtain positions, with particular attention to energy productivity, specific energy, net energy, and energy ratio. The greenhouses are used for strawberry production. In the R-greenhouse (RGH), the thermal curtain hanged directly at the roof ridge, whereas in the Q-greenhouse (QGH), the thermal curtain was placed 5° from an imaginary vertical axis, from the middle of the roof ridge downwards to the north side of the greenhouse roof. The relevant data were recorded using standard methods. The results indicated that the energy expended in the RGH and QGH systems was 2,186.48 and 2,189.26 MJ/m2, respectively. Electricity and nitrogen fertilizer contributed the highest energy input in both greenhouses and in all seasons. The output energy was 3.12 and 3.82 MJ/m2, respectively, in RGH and QGH in season I and 4.40 and 4.87 MJ/m2 in season II. In terms of energy expended, there was no significant difference between the two greenhouses, nor between the two seasons. These results indicate that greenhouses of the size used in this investigation are not viable in terms of energy productivity, energy-use efficiency, and subsequent economic performance. However, further studies should be conducted to scaleup the information obtained from this investigation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyeon Tae photo

Kim, Hyeon Tae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE