Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of input-output energy use in strawberry production in single-span double-layered greenhouses with different thermal-curtain positions

Full metadata record
DC Field Value Language
dc.contributor.authorTimothy Denen Akpenpuun-
dc.contributor.author나욱호-
dc.contributor.authorQazeem Opeyemi Ogunlowo-
dc.contributor.authorAnis Rabiu-
dc.contributor.authorMisbaudeen Aderemi Adesanya-
dc.contributor.authorPrabhat Dutta-
dc.contributor.authorEzatullah Zakir-
dc.contributor.author김현태-
dc.contributor.author이현우-
dc.date.accessioned2023-10-20T08:43:22Z-
dc.date.available2023-10-20T08:43:22Z-
dc.date.issued2023-09-
dc.identifier.issn2466-2402-
dc.identifier.issn2466-2410-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/68189-
dc.description.abstractThe large amount of energy required for successful crop production is the main challenge in greenhouse cropping systems. As a response to this challenge a comprehensive evaluation of greenhouse energy consumption was carried out in two structurally similar single-span greenhouses with different thermal curtain positions, with particular attention to energy productivity, specific energy, net energy, and energy ratio. The greenhouses are used for strawberry production. In the R-greenhouse (RGH), the thermal curtain hanged directly at the roof ridge, whereas in the Q-greenhouse (QGH), the thermal curtain was placed 5° from an imaginary vertical axis, from the middle of the roof ridge downwards to the north side of the greenhouse roof. The relevant data were recorded using standard methods. The results indicated that the energy expended in the RGH and QGH systems was 2,186.48 and 2,189.26 MJ/m2, respectively. Electricity and nitrogen fertilizer contributed the highest energy input in both greenhouses and in all seasons. The output energy was 3.12 and 3.82 MJ/m2, respectively, in RGH and QGH in season I and 4.40 and 4.87 MJ/m2 in season II. In terms of energy expended, there was no significant difference between the two greenhouses, nor between the two seasons. These results indicate that greenhouses of the size used in this investigation are not viable in terms of energy productivity, energy-use efficiency, and subsequent economic performance. However, further studies should be conducted to scaleup the information obtained from this investigation.-
dc.format.extent12-
dc.language영어-
dc.language.isoENG-
dc.publisher충남대학교 농업과학연구소-
dc.titleEvaluation of input-output energy use in strawberry production in single-span double-layered greenhouses with different thermal-curtain positions-
dc.title.alternativeEvaluation of input-output energy use in strawberry production in single-span double-layered greenhouses with different thermal-curtain positions-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.7744/kjoas.500309-
dc.identifier.bibliographicCitationKorean Journal of Agricultural Science, v.50, no.3, pp 395 - 406-
dc.citation.titleKorean Journal of Agricultural Science-
dc.citation.volume50-
dc.citation.number3-
dc.citation.startPage395-
dc.citation.endPage406-
dc.identifier.kciidART002997217-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthoranalysis-
dc.subject.keywordAuthorenergy-
dc.subject.keywordAuthorinput-output-
dc.subject.keywordAuthorproductivity-
dc.subject.keywordAuthorratios-
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyeon Tae photo

Kim, Hyeon Tae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE