충격기류식 여과집진장치의 펄스간격 및 분사거리에 따른 압력손실변화에 관한 기초 연구A Study on the Pressure drop Variance of Pulse interval,injection distance in Pulse Air Jet Type Bag Filter

Other Titles
A Study on the Pressure drop Variance of Pulse interval,injection distance in Pulse Air Jet Type Bag Filter
Authors
서정민최금찬박정호
Issue Date
2004
Publisher
한국환경과학회
Keywords
Pressure drop; Injection distance; Pulse interval; Concentration; Pressure drop; Injection distance; Pulse interval; Concentration
Citation
한국환경과학회지, v.13, no.3, pp 223 - 232
Pages
10
Indexed
KCI
Journal Title
한국환경과학회지
Volume
13
Number
3
Start Page
223
End Page
232
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/29225
ISSN
1225-4517
2287-3503
Abstract
The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to 50mmH2O varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/m3 and 1g/m3, the pressure drop(ΔP) was stable 60 to 90minutes after operation. For the higher concentration of 3g/m3, as ΔP continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 110mm, when inlet dust concentration is 0.5g/m3 or 1g/m3, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/m3 and 3g/m3 has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.
Files in This Item
There are no files associated with this item.
Appears in
Collections
건설환경공과대학 > 환경공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jeong Ho photo

Park, Jeong Ho
건설환경공과대학 (환경공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE