Cited 0 time in
충격기류식 여과집진장치의 펄스간격 및 분사거리에 따른 압력손실변화에 관한 기초 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 서정민 | - |
| dc.contributor.author | 최금찬 | - |
| dc.contributor.author | 박정호 | - |
| dc.date.accessioned | 2022-12-27T07:38:14Z | - |
| dc.date.available | 2022-12-27T07:38:14Z | - |
| dc.date.issued | 2004 | - |
| dc.identifier.issn | 1225-4517 | - |
| dc.identifier.issn | 2287-3503 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/29225 | - |
| dc.description.abstract | The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to 50mmH2O varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/m3 and 1g/m3, the pressure drop(ΔP) was stable 60 to 90minutes after operation. For the higher concentration of 3g/m3, as ΔP continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 110mm, when inlet dust concentration is 0.5g/m3 or 1g/m3, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/m3 and 3g/m3 has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm. | - |
| dc.format.extent | 10 | - |
| dc.publisher | 한국환경과학회 | - |
| dc.title | 충격기류식 여과집진장치의 펄스간격 및 분사거리에 따른 압력손실변화에 관한 기초 연구 | - |
| dc.title.alternative | A Study on the Pressure drop Variance of Pulse interval,injection distance in Pulse Air Jet Type Bag Filter | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국환경과학회지, v.13, no.3, pp 223 - 232 | - |
| dc.citation.title | 한국환경과학회지 | - |
| dc.citation.volume | 13 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 223 | - |
| dc.citation.endPage | 232 | - |
| dc.identifier.kciid | ART000937779 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Pressure drop | - |
| dc.subject.keywordAuthor | Injection distance | - |
| dc.subject.keywordAuthor | Pulse interval | - |
| dc.subject.keywordAuthor | Concentration | - |
| dc.subject.keywordAuthor | Pressure drop | - |
| dc.subject.keywordAuthor | Injection distance | - |
| dc.subject.keywordAuthor | Pulse interval | - |
| dc.subject.keywordAuthor | Concentration | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.