Reuse of a dyehouse effluent after being treated with the combined catalytic wet peroxide oxidation process and the aerated constructed wetland
- Authors
- Lee, D.-K.; Kim, S.-C.; Yoon, J.-H.
- Issue Date
- 2007
- Publisher
- IWA PUBLISHING
- Keywords
- aerated constructed wetland; catalytic wet peroxide oxidation; dyehouse wastewaters; water reuse
- Citation
- WATER SCIENCE AND TECHNOLOGY, v.55, no.1-2, pp 407 - 415
- Pages
- 9
- Indexed
- SCIE
SCOPUS
- Journal Title
- WATER SCIENCE AND TECHNOLOGY
- Volume
- 55
- Number
- 1-2
- Start Page
- 407
- End Page
- 415
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/29064
- DOI
- 10.2166/wst.2007.041
- ISSN
- 0273-1223
1996-9732
- Abstract
- A catalytic wet peroxide oxidation process was combined with the aerated constructed wetland in order to treat the raw dyehouse wastewater to in acceptable level for reuse as washing process water. More than 90% of BOD and CODs could be removed with the wet peroxide oxidation reactor and the remaining pollutants in the treated water were transformed into biodegradable ones which could have been successfully treated at the following aerated constructed wetland. The highest values of BOD5, CODMn, CODCr, SS and T-N in the treated water were 1.6, 1.8, 2.1, 0.5 and 12.8 mg/L, respectively. These values were low enough for the treated water to be reused at the washing process.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 공과대학 > 화학공학과 > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.