Reuse of a dyehouse effluent after being treated with the combined catalytic wet peroxide oxidation process and the aerated constructed wetland
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, D.-K. | - |
| dc.contributor.author | Kim, S.-C. | - |
| dc.contributor.author | Yoon, J.-H. | - |
| dc.date.accessioned | 2022-12-27T07:33:35Z | - |
| dc.date.available | 2022-12-27T07:33:35Z | - |
| dc.date.issued | 2007 | - |
| dc.identifier.issn | 0273-1223 | - |
| dc.identifier.issn | 1996-9732 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/29064 | - |
| dc.description.abstract | A catalytic wet peroxide oxidation process was combined with the aerated constructed wetland in order to treat the raw dyehouse wastewater to in acceptable level for reuse as washing process water. More than 90% of BOD and CODs could be removed with the wet peroxide oxidation reactor and the remaining pollutants in the treated water were transformed into biodegradable ones which could have been successfully treated at the following aerated constructed wetland. The highest values of BOD5, CODMn, CODCr, SS and T-N in the treated water were 1.6, 1.8, 2.1, 0.5 and 12.8 mg/L, respectively. These values were low enough for the treated water to be reused at the washing process. | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IWA PUBLISHING | - |
| dc.title | Reuse of a dyehouse effluent after being treated with the combined catalytic wet peroxide oxidation process and the aerated constructed wetland | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.2166/wst.2007.041 | - |
| dc.identifier.scopusid | 2-s2.0-33846916494 | - |
| dc.identifier.wosid | 000245786000050 | - |
| dc.identifier.bibliographicCitation | WATER SCIENCE AND TECHNOLOGY, v.55, no.1-2, pp 407 - 415 | - |
| dc.citation.title | WATER SCIENCE AND TECHNOLOGY | - |
| dc.citation.volume | 55 | - |
| dc.citation.number | 1-2 | - |
| dc.citation.startPage | 407 | - |
| dc.citation.endPage | 415 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
| dc.relation.journalResearchArea | Water Resources | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
| dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
| dc.relation.journalWebOfScienceCategory | Water Resources | - |
| dc.subject.keywordPlus | AIR OXIDATION | - |
| dc.subject.keywordPlus | CARBOXYLIC-ACIDS | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordAuthor | aerated constructed wetland | - |
| dc.subject.keywordAuthor | catalytic wet peroxide oxidation | - |
| dc.subject.keywordAuthor | dyehouse wastewaters | - |
| dc.subject.keywordAuthor | water reuse | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.