Cited 0 time in
다축 힘/모멘트 센서 교정기의 개발 및 그의 불확도 평가
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김갑순 | - |
| dc.contributor.author | 윤정원 | - |
| dc.date.accessioned | 2022-12-27T07:09:22Z | - |
| dc.date.available | 2022-12-27T07:09:22Z | - |
| dc.date.issued | 2007 | - |
| dc.identifier.issn | 1225-9071 | - |
| dc.identifier.issn | 2287-8769 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/28677 | - |
| dc.description.abstract | This paper describes the development of the calibration system for a multi-axis force/moment sensor and its uncertainty evaluation. This calibration system can generate the continuous forces (Fx, Fy and Fz) and moments (Mx, My and Mz). Many kinds of multi-axis force/moment sensors in industries should be carried out the characteristic test or the calibration with the calibration system that can generate the forces and the moments. The calibration systems have been already developed are the disadvantages of the low capacity, the generation of step forces(10N, 20N ) and step moments(1Nm, 2Nm ) with weights, the high coasts in manufacture and so on. In this paper, the calibration system for a multi-axis force/moment sensor that can generate the continuous three forces and three moments was developed. Their ranges are 0~2000N in all force-directions and 0~400Nm in all moment-directions. And the system was evaluated in the expanded relative uncertainty. They were 0.0004 in all forces Fx , Fy and Fz, and 0.0004 in all moments Mx, My and Mz. | - |
| dc.format.extent | 8 | - |
| dc.publisher | 한국정밀공학회 | - |
| dc.title | 다축 힘/모멘트 센서 교정기의 개발 및 그의 불확도 평가 | - |
| dc.title.alternative | Development of Calibration System for Multi-Axis Force/Moment Sensor and Its Uncertainty Evaluation | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국정밀공학회지, v.24, no.10, pp 91 - 98 | - |
| dc.citation.title | 한국정밀공학회지 | - |
| dc.citation.volume | 24 | - |
| dc.citation.number | 10 | - |
| dc.citation.startPage | 91 | - |
| dc.citation.endPage | 98 | - |
| dc.identifier.kciid | ART001074107 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Multi-axis force/moment sensor calibration system (다축 힘/모멘트 센서 교정장치) | - |
| dc.subject.keywordAuthor | Expanded relative uncertainty (확장상대불확도) | - |
| dc.subject.keywordAuthor | Multi-axis force/moment sensor (다축 힘/모멘트 센서) | - |
| dc.subject.keywordAuthor | Calibration (교정) | - |
| dc.subject.keywordAuthor | Characteristic test(특성시험) | - |
| dc.subject.keywordAuthor | Multi-axis force/moment sensor calibration system (다축 힘/모멘트 센서 교정장치) | - |
| dc.subject.keywordAuthor | Expanded relative uncertainty (확장상대불확도) | - |
| dc.subject.keywordAuthor | Multi-axis force/moment sensor (다축 힘/모멘트 센서) | - |
| dc.subject.keywordAuthor | Calibration (교정) | - |
| dc.subject.keywordAuthor | Characteristic test(특성시험) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.