Design of a six-axis wrist force/moment sensor using FEM and its fabrication for an intelligent robot
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Gab-Soon | - |
| dc.date.accessioned | 2022-12-27T07:04:19Z | - |
| dc.date.available | 2022-12-27T07:04:19Z | - |
| dc.date.issued | 2007-01-08 | - |
| dc.identifier.issn | 0924-4247 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/28468 | - |
| dc.description.abstract | This paper describes the design of a six-axis force/moment sensor using FEM (finite element method) and its fabrication. In order to safely grasp an unknown object using an intelligent hand in robot, the band has to perceive the weight of it. The weight is calculated by forces F(x), F(y), F(z) measured from the six-axis wrist force/moment sensor attached to an intelligent robot's hand. And, in order to accurately push and pull an object, forces and moments should be measured. Also, the position of the robot's finger contacted on an object are calculated by forces F(x), F(y) and F(z) and moments M(x), M(y), and M(z) measured from the six-axis wrist force/moment sensor. Therefore, an intelligent robot's hand should get a six-axis wrist force/moment sensor that can measure forces F(x), F(y), and F(z), and moments M(x), M(y), and M(z), simultaneously. The size of the six-axis force/moment sensor for an intelligent robot' wrist is very important. If its diameter is larger or its thickness (length) is longer, it cannot be mounted in robot's wrist or it will break down under the applied moment M(x), or M(y). So, its size is similar to that of the wrist of human being, that is, the diameter is about 60-80 mm and the thickness (length) about 20-40 mm. But the manufactured sensors are not proper in size for the intelligent robot's wrist. Thus, the six-axis force/moment sensor should be developed for the intelligent robot's wrist. In this paper, the structure of a six-axis wrist force/moment sensor was modeled for an intelligent hand in robot newly. And the sensing elements of it were designed by using FEM and were fabricated by attaching strain-gages on the sensing elements. And, the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with the results from the experiments. The interference error of the sensor is less than 2.85%. (c) 2006 Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | ELSEVIER SCIENCE SA | - |
| dc.title | Design of a six-axis wrist force/moment sensor using FEM and its fabrication for an intelligent robot | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.1016/j.sna.2006.03.038 | - |
| dc.identifier.scopusid | 2-s2.0-33845571080 | - |
| dc.identifier.wosid | 000243622900005 | - |
| dc.identifier.bibliographicCitation | SENSORS AND ACTUATORS A-PHYSICAL, v.133, no.1, pp 27 - 34 | - |
| dc.citation.title | SENSORS AND ACTUATORS A-PHYSICAL | - |
| dc.citation.volume | 133 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 27 | - |
| dc.citation.endPage | 34 | - |
| dc.type.docType | Review | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | HANDS | - |
| dc.subject.keywordPlus | UNCERTAINTY | - |
| dc.subject.keywordAuthor | intelligent robot | - |
| dc.subject.keywordAuthor | six-axis wrist force/moment sensor | - |
| dc.subject.keywordAuthor | interference error | - |
| dc.subject.keywordAuthor | rated output | - |
| dc.subject.keywordAuthor | intelligent hand | - |
| dc.subject.keywordAuthor | robot's finger | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.