무창이유자돈사의 내부 환경 개선에 관한 연구Study on Modification of Inside Environment in Windowless Weaning Piglet House
- Other Titles
- Study on Modification of Inside Environment in Windowless Weaning Piglet House
- Authors
- 이승주; W. M. Gutierrez; 김봉식; 한진영; 장동일; 장홍희
- Issue Date
- 2008
- Publisher
- 한국환경농학회
- Keywords
- ventilation; weaning piglet house; CFD simulation; air inlet; air outlet
- Citation
- 한국환경농학회지, v.27, no.2, pp 150 - 155
- Pages
- 6
- Indexed
- KCI
- Journal Title
- 한국환경농학회지
- Volume
- 27
- Number
- 2
- Start Page
- 150
- End Page
- 155
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/27947
- ISSN
- 1225-3537
2233-4173
- Abstract
- This study was carried out to determinate the location and the number of air inlet and outlet, optimum air inlet velocity for effective ventilation in windowless weaning piglet house (2.90(W)× 9.90(L)×2.80(H) m) by CFD (Computation Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 11 air inlets and 9 outlets, modified and simulated using CFD code, FLUENT. The simulation result for the original weaning piglet house, which was not modified, showed ununiform ventilation for each room. Therefore, for uniform ventilation, 4 air inlets and 1 outlet were completely closed, and 2 air outlets were partially closed. The simulation result for the modified weaning piglet house showed uniform ventilation for each room and the optimum air inlet velocity of 0.5 m sec-1.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 농업생명과학대학 > 축산과학부 > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.