Cited 0 time in
무창이유자돈사의 내부 환경 개선에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이승주 | - |
| dc.contributor.author | W. M. Gutierrez | - |
| dc.contributor.author | 김봉식 | - |
| dc.contributor.author | 한진영 | - |
| dc.contributor.author | 장동일 | - |
| dc.contributor.author | 장홍희 | - |
| dc.date.accessioned | 2022-12-27T06:35:59Z | - |
| dc.date.available | 2022-12-27T06:35:59Z | - |
| dc.date.issued | 2008 | - |
| dc.identifier.issn | 1225-3537 | - |
| dc.identifier.issn | 2233-4173 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/27947 | - |
| dc.description.abstract | This study was carried out to determinate the location and the number of air inlet and outlet, optimum air inlet velocity for effective ventilation in windowless weaning piglet house (2.90(W)× 9.90(L)×2.80(H) m) by CFD (Computation Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 11 air inlets and 9 outlets, modified and simulated using CFD code, FLUENT. The simulation result for the original weaning piglet house, which was not modified, showed ununiform ventilation for each room. Therefore, for uniform ventilation, 4 air inlets and 1 outlet were completely closed, and 2 air outlets were partially closed. The simulation result for the modified weaning piglet house showed uniform ventilation for each room and the optimum air inlet velocity of 0.5 m sec-1. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국환경농학회 | - |
| dc.title | 무창이유자돈사의 내부 환경 개선에 관한 연구 | - |
| dc.title.alternative | Study on Modification of Inside Environment in Windowless Weaning Piglet House | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국환경농학회지, v.27, no.2, pp 150 - 155 | - |
| dc.citation.title | 한국환경농학회지 | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 150 | - |
| dc.citation.endPage | 155 | - |
| dc.identifier.kciid | ART001261894 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | ventilation | - |
| dc.subject.keywordAuthor | weaning piglet house | - |
| dc.subject.keywordAuthor | CFD simulation | - |
| dc.subject.keywordAuthor | air inlet | - |
| dc.subject.keywordAuthor | air outlet | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.