Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

원통형 4손가락 힘측정시스템 개발

Full metadata record
DC Field Value Language
dc.contributor.author김갑순-
dc.date.accessioned2022-12-27T04:36:26Z-
dc.date.available2022-12-27T04:36:26Z-
dc.date.issued2010-
dc.identifier.issn1225-5475-
dc.identifier.issn2093-7563-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/25587-
dc.description.abstractStroke patients, etc. can’t use their hands because of the paralysis of their fingers, and their fingers could be recovered by rehabilitating training. In order to judge the rehabilitating extent of their fingers, the patients should grasp a cylindrical object in hospital. At present, the used object in hospital is only a cylindrical object, and can’t measure the force of fingers. Therefore, doctors judge the rehabilitating extent by touching and watching at their fingers. So, the four-finger force measuring system which can measure the force of their fingers should be developed. In this paper, four-finger force measuring system with four force sensors which can measure the grasping force is developed. The force sensors are designed and fabricated, and the force measuring device is designed and manufactured by using DSP(digital signal processing). Also, the grasping force test of men is performed by using the developed four-finger force measuring system. It was confirmed that the finger average force of right hand is about 214.6 N and that of left hand is about 212.8 N.-
dc.format.extent7-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국센서학회-
dc.title원통형 4손가락 힘측정시스템 개발-
dc.title.alternativeDevelopment of four-finger force measuring system of a cylindrical type-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation센서학회지, v.19, no.5, pp 349 - 355-
dc.citation.title센서학회지-
dc.citation.volume19-
dc.citation.number5-
dc.citation.startPage349-
dc.citation.endPage355-
dc.identifier.kciidART001482656-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorforce sensor-
dc.subject.keywordAuthorfinger force-
dc.subject.keywordAuthorfinger rehabilitation-
dc.subject.keywordAuthorrehabilitating instrument-
dc.subject.keywordAuthorcylindrical object prehension-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 제어계측공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Gab Soon photo

Kim, Gab Soon
IT공과대학 (제어로봇공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE