Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

뇌졸중 환자의 손 고정장치 제어를 위한 다축 힘/모멘트센서 개발

Full metadata record
DC Field Value Language
dc.contributor.author김현민-
dc.contributor.author윤정원-
dc.contributor.author김갑순-
dc.date.accessioned2022-12-27T03:33:03Z-
dc.date.available2022-12-27T03:33:03Z-
dc.date.issued2011-
dc.identifier.issn1225-5475-
dc.identifier.issn2093-7563-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/24259-
dc.description.abstractStroke patients should exercise for the rehabilitation of their fingers, because they can’t use their hand and fingers. Their hand and fingers are fixed on the hand fixing system for rehabilitation exercise of them. But the hands clenched the fist of stroke patients are difficult to fix on it. In order to fix the hands and fingers, their palms are pressed with pressing bars and are controlled by reference force. The fixing system must have a five-axis force/moment sensor to force control. In this paper, the five-axis force/moment sensor was developed for the hand fixing system of finger-rehabilitation exercising system. The structure of the five-axis force/moment sensor was modeled, and designed using finite element method(FEM). And it was fabricated with strain-gages, then, its characteristic test was carried out. As a result, the maximum interference error is less than 2.43 %.-
dc.format.extent6-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국센서학회-
dc.title뇌졸중 환자의 손 고정장치 제어를 위한 다축 힘/모멘트센서 개발-
dc.title.alternativeDevelopment of Multi-Axis Force/Moment Sensor for Stroke Patient’s Hand Fixing System Control-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation센서학회지, v.20, no.5, pp 351 - 356-
dc.citation.title센서학회지-
dc.citation.volume20-
dc.citation.number5-
dc.citation.startPage351-
dc.citation.endPage356-
dc.identifier.kciidART001589781-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorFive-Axis Force/Moment Sensor-
dc.subject.keywordAuthorInterference Error-
dc.subject.keywordAuthorRated Output-
dc.subject.keywordAuthorRehabilitation Robot-
dc.subject.keywordAuthorFinger Rehabilitation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > 제어계측공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Gab Soon photo

Kim, Gab Soon
IT공과대학 (제어로봇공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE