Cited 0 time in
뇌졸중 환자의 손 고정장치 제어를 위한 다축 힘/모멘트센서 개발
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김현민 | - |
| dc.contributor.author | 윤정원 | - |
| dc.contributor.author | 김갑순 | - |
| dc.date.accessioned | 2022-12-27T03:33:03Z | - |
| dc.date.available | 2022-12-27T03:33:03Z | - |
| dc.date.issued | 2011 | - |
| dc.identifier.issn | 1225-5475 | - |
| dc.identifier.issn | 2093-7563 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/24259 | - |
| dc.description.abstract | Stroke patients should exercise for the rehabilitation of their fingers, because they can’t use their hand and fingers. Their hand and fingers are fixed on the hand fixing system for rehabilitation exercise of them. But the hands clenched the fist of stroke patients are difficult to fix on it. In order to fix the hands and fingers, their palms are pressed with pressing bars and are controlled by reference force. The fixing system must have a five-axis force/moment sensor to force control. In this paper, the five-axis force/moment sensor was developed for the hand fixing system of finger-rehabilitation exercising system. The structure of the five-axis force/moment sensor was modeled, and designed using finite element method(FEM). And it was fabricated with strain-gages, then, its characteristic test was carried out. As a result, the maximum interference error is less than 2.43 %. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국센서학회 | - |
| dc.title | 뇌졸중 환자의 손 고정장치 제어를 위한 다축 힘/모멘트센서 개발 | - |
| dc.title.alternative | Development of Multi-Axis Force/Moment Sensor for Stroke Patient’s Hand Fixing System Control | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 센서학회지, v.20, no.5, pp 351 - 356 | - |
| dc.citation.title | 센서학회지 | - |
| dc.citation.volume | 20 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 351 | - |
| dc.citation.endPage | 356 | - |
| dc.identifier.kciid | ART001589781 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Five-Axis Force/Moment Sensor | - |
| dc.subject.keywordAuthor | Interference Error | - |
| dc.subject.keywordAuthor | Rated Output | - |
| dc.subject.keywordAuthor | Rehabilitation Robot | - |
| dc.subject.keywordAuthor | Finger Rehabilitation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.