Cited 1 time in
Design of rectangular-type four-finger rehabilitation robot for stroke patient
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, H.-M. | - |
| dc.contributor.author | Kim, G.-S. | - |
| dc.date.accessioned | 2022-12-27T01:31:49Z | - |
| dc.date.available | 2022-12-27T01:31:49Z | - |
| dc.date.issued | 2013 | - |
| dc.identifier.issn | 1976-5622 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/21774 | - |
| dc.description.abstract | This paper describes the design of a rectangular-type four-finger rehabilitation robot for flexibility rehabilitation of stroke patients' fingers and other patient's paralyzed fingers. The four-finger rehabilitation robot is composed of a body and each finger rehabilitation robot instrument. The four-finger rehabilitation robot could exercise four fingers (forefinger, middle finger ring finger and little finger) of patient for their rehabilitation. The four-finger rehabilitation robot instruments move according to the trace which spread out the patient's fingers and then turn them inward for the fingers' flexibility, while at the same time performing the force control with the reference forces for fingers' safety, simultaneously. A control characteristic test of the developed rectangular-type four-finger rehabilitation robot was carried out, and the results confirmed that the robot could be used for the flexibility rehabilitation exercise for the fingers of normal person and patients. ? ICROS 2013. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.title | Design of rectangular-type four-finger rehabilitation robot for stroke patient | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5302/J.ICROS.2013.12.1840 | - |
| dc.identifier.scopusid | 2-s2.0-84887199998 | - |
| dc.identifier.bibliographicCitation | Journal of Institute of Control, Robotics and Systems, v.19, no.5, pp 473 - 480 | - |
| dc.citation.title | Journal of Institute of Control, Robotics and Systems | - |
| dc.citation.volume | 19 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 473 | - |
| dc.citation.endPage | 480 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001767176 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Finger rehabilitation | - |
| dc.subject.keywordAuthor | Interference error | - |
| dc.subject.keywordAuthor | Rated output | - |
| dc.subject.keywordAuthor | Rehabilitation robot | - |
| dc.subject.keywordAuthor | Two-axis force sensor | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.