Cited 5 time in
Design of two-axis force/torque sensor for hip joint rehabilitation robot
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, H.-S. | - |
| dc.contributor.author | Kim, G.-S. | - |
| dc.date.accessioned | 2022-12-26T21:16:22Z | - |
| dc.date.available | 2022-12-26T21:16:22Z | - |
| dc.date.issued | 2016 | - |
| dc.identifier.issn | 1976-5622 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/16668 | - |
| dc.description.abstract | We describe the design and fabrication of a two-axis force/torque sensor with parallel-plate beams (PPBs) and single beams for measuring force and torque in hip-joint rehabilitation exercise using a lower rehabilitation robot. The two-axis force/torque sensor is composed of an Fz force sensor and a Tz torque sensor, which detect z direction force and z direction torque, respectively. The two-axis force/torque sensor was designed using the FEM (Finite Element Method) and manufactured using strain gages. The characteristics experiment of the two-axis force/torque sensor was carried out. The test results show that the interference error of the two-axis force/torque sensor was less than 0.64% and the repeatability error and the non-linearity of the two-axis force/torque sensor were less than 0.03%. It is thought that the developed two-axis force/torque sensor could be used for a lower rehabilitation robot. ? ICROS 2016. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | Institute of Control, Robotics and Systems | - |
| dc.title | Design of two-axis force/torque sensor for hip joint rehabilitation robot | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5302/J.ICROS.2016.16.0067 | - |
| dc.identifier.scopusid | 2-s2.0-84995873409 | - |
| dc.identifier.bibliographicCitation | Journal of Institute of Control, Robotics and Systems, v.22, no.7, pp 524 - 529 | - |
| dc.citation.title | Journal of Institute of Control, Robotics and Systems | - |
| dc.citation.volume | 22 | - |
| dc.citation.number | 7 | - |
| dc.citation.startPage | 524 | - |
| dc.citation.endPage | 529 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002120991 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Hip-joint rehabilitation | - |
| dc.subject.keywordAuthor | Interference error | - |
| dc.subject.keywordAuthor | Nolinearity error | - |
| dc.subject.keywordAuthor | Rated output | - |
| dc.subject.keywordAuthor | Repeatability error | - |
| dc.subject.keywordAuthor | Strain gage | - |
| dc.subject.keywordAuthor | Two-axis force/torque sensor | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
