Cited 0 time in
중증뇌졸중환자의 발목재활로봇을 위한 힘센서 설계
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김한솔 | - |
| dc.contributor.author | 김갑순 | - |
| dc.date.accessioned | 2022-12-26T21:02:38Z | - |
| dc.date.available | 2022-12-26T21:02:38Z | - |
| dc.date.issued | 2016-03 | - |
| dc.identifier.issn | 1225-5475 | - |
| dc.identifier.issn | 2093-7563 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/16454 | - |
| dc.description.abstract | This paper describes the design and fabrication of a two-axis force/torque sensor and an one-axis force sensor with parallel plate beams(PPSs) for measuring forces and torque in an ankle rehabilitation exercise using by a lower rehabilitation robot. The two-axis force/torque sensor is composed of a Fy force sensor and Tz torque sensor and the force sensor detects x direction force. The two-axis force/torque sensor and one-axis force sensor were designed using by FEM(Finite Element Method), and manufactured using strain-gages. The characteristics experiment of the two-axis force/torque sensor and one-axis force sensor were carried out respectively. As a test results, the interference error of the two-axis force/torque sensor was less than 1.56%, the repeatability error and the non-linearity of the two-axis force/torque sensor were less than 0.03% respectively, and the repeatability error and the non-linearity of the one-axis force sensor were less than 0.03% and 0.02% respectively. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국센서학회 | - |
| dc.title | 중증뇌졸중환자의 발목재활로봇을 위한 힘센서 설계 | - |
| dc.title.alternative | Design of Force Sensors for the Ankle Rehabilitation Robot of Severe Stroke Patients | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5369/JSST.2016.25.2.148 | - |
| dc.identifier.bibliographicCitation | 센서학회지, v.25, no.2, pp 148 - 154 | - |
| dc.citation.title | 센서학회지 | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 148 | - |
| dc.citation.endPage | 154 | - |
| dc.identifier.kciid | ART002094581 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Two-axis force sensor | - |
| dc.subject.keywordAuthor | Force sensor | - |
| dc.subject.keywordAuthor | Rated output | - |
| dc.subject.keywordAuthor | Interference error | - |
| dc.subject.keywordAuthor | Ankle force | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
