Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

500 PS SCR 반응기 혼합증발관 길이와 각도 변화에 따른 유동균일도에 대한 수치해석적 연구open accessA Study on Numerical Analysis of Flow Uniformity According to Length and Degree Change of Mixed-Evaporator in 500 PS SCR Reactor

Other Titles
A Study on Numerical Analysis of Flow Uniformity According to Length and Degree Change of Mixed-Evaporator in 500 PS SCR Reactor
Authors
성홍석이충호서정세
Issue Date
2016
Publisher
대한설비공학회
Keywords
ASCR(선택적 환원 촉매); Flow uniformity(유동균일도); Mixed-evaporator(혼합증발관); CFD(전산유체역학)
Citation
설비공학 논문집, v.28, no.8, pp 337 - 342
Pages
6
Indexed
KCI
Journal Title
설비공학 논문집
Volume
28
Number
8
Start Page
337
End Page
342
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/16282
DOI
10.6110/KJACR.2016.28.8.337
ISSN
1229-6422
2465-7611
Abstract
A marine SCR System is emerging as an alternative to comply with NOx Tier III Emission standards, a restriction on greenhouse gas from vessels implemented by the International Maritime Organization. The system is greatly affected by the uniformity of the fluid flowing into the catalyst, so the performance of the catalyst of an SCR system needs to be guaranteed. This study conducted research on a mixed evaporator of an SCR system, which is one of the factors affecting the uniformity of the fluid. When the angle of the mixed evaporator is set to 90°, the fluid uniformity is at its highest at 83%, under the condition that the length of the mixed evaporator be 3.5D. When the length was 3.5D and less, the fluid uniformity had a tendency to improve relative to the case without a bent pipe. However, a longer mixed evaporator results in a more perfect liquidity development in the pipe with a liquidity distribution similar to the case where no curved pipe is formed in front of the catalyst. A lower angle for the mixed evaporator results in a lower flow uniformity, and a longer length of the mixed evaporator results in a lower difference in the flow uniformity caused by the angle. The flow uniformity can be improved by 6% with a mixed evaporator, which confirmed that all factors applied to an SCR system have a close relationship with the efficiency.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > Department of Mechanical Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Suh, Jeong Se photo

Suh, Jeong Se
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE