Cited 0 time in
500 PS SCR 반응기 혼합증발관 길이와 각도 변화에 따른 유동균일도에 대한 수치해석적 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 성홍석 | - |
| dc.contributor.author | 이충호 | - |
| dc.contributor.author | 서정세 | - |
| dc.date.accessioned | 2022-12-26T20:48:43Z | - |
| dc.date.available | 2022-12-26T20:48:43Z | - |
| dc.date.issued | 2016 | - |
| dc.identifier.issn | 1229-6422 | - |
| dc.identifier.issn | 2465-7611 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/16282 | - |
| dc.description.abstract | A marine SCR System is emerging as an alternative to comply with NOx Tier III Emission standards, a restriction on greenhouse gas from vessels implemented by the International Maritime Organization. The system is greatly affected by the uniformity of the fluid flowing into the catalyst, so the performance of the catalyst of an SCR system needs to be guaranteed. This study conducted research on a mixed evaporator of an SCR system, which is one of the factors affecting the uniformity of the fluid. When the angle of the mixed evaporator is set to 90°, the fluid uniformity is at its highest at 83%, under the condition that the length of the mixed evaporator be 3.5D. When the length was 3.5D and less, the fluid uniformity had a tendency to improve relative to the case without a bent pipe. However, a longer mixed evaporator results in a more perfect liquidity development in the pipe with a liquidity distribution similar to the case where no curved pipe is formed in front of the catalyst. A lower angle for the mixed evaporator results in a lower flow uniformity, and a longer length of the mixed evaporator results in a lower difference in the flow uniformity caused by the angle. The flow uniformity can be improved by 6% with a mixed evaporator, which confirmed that all factors applied to an SCR system have a close relationship with the efficiency. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한설비공학회 | - |
| dc.title | 500 PS SCR 반응기 혼합증발관 길이와 각도 변화에 따른 유동균일도에 대한 수치해석적 연구 | - |
| dc.title.alternative | A Study on Numerical Analysis of Flow Uniformity According to Length and Degree Change of Mixed-Evaporator in 500 PS SCR Reactor | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.6110/KJACR.2016.28.8.337 | - |
| dc.identifier.bibliographicCitation | 설비공학 논문집, v.28, no.8, pp 337 - 342 | - |
| dc.citation.title | 설비공학 논문집 | - |
| dc.citation.volume | 28 | - |
| dc.citation.number | 8 | - |
| dc.citation.startPage | 337 | - |
| dc.citation.endPage | 342 | - |
| dc.identifier.kciid | ART002132820 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | ASCR(선택적 환원 촉매) | - |
| dc.subject.keywordAuthor | Flow uniformity(유동균일도) | - |
| dc.subject.keywordAuthor | Mixed-evaporator(혼합증발관) | - |
| dc.subject.keywordAuthor | CFD(전산유체역학) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.