Cited 5 time in
Design of a force sensor for thigh force measurement of a wearable
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jung, J.-H. | - |
| dc.contributor.author | Kim, G.S. | - |
| dc.date.accessioned | 2022-12-26T19:47:22Z | - |
| dc.date.available | 2022-12-26T19:47:22Z | - |
| dc.date.issued | 2017 | - |
| dc.identifier.issn | 1225-9071 | - |
| dc.identifier.issn | 2287-8769 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/14958 | - |
| dc.description.abstract | We describe the design and fabrication of a three-axis force sensor with parallel plate beams (PPBs) for measuring the force of a patient's thigh in a wearable walking robot. The thigh link three-axis force sensor is composed of Fx force sensor, Fy force sensor, Fz force sensor and a pulley, which detect the x, y and z direction forces, respectively The three-axis force sensor was designed using the Finite Element Method (FEM), and manufactured using strain-gages. Experiments to evaluate the characteristics of the three-axis force sensor were carried out. The results of the characteristics experiment indicate that the repeatability error and the non-linearity of the three-axis force sensor was less than 0.04%, and the results for calibration showed that the errors of the sensor was less than 0.1%. Therefore, the fabricated thigh link three-axis force sensor can be used to measure the patient's thigh force of the wearable walking robot. Copyright ? The Korean Society for Precision Engineering. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | Korean Society for Precision Engineeing | - |
| dc.title | Design of a force sensor for thigh force measurement of a wearable | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.7736/KSPE.2017.34.10.707 | - |
| dc.identifier.scopusid | 2-s2.0-85033556029 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Society for Precision Engineering, v.34, no.10, pp 707 - 713 | - |
| dc.citation.title | Journal of the Korean Society for Precision Engineering | - |
| dc.citation.volume | 34 | - |
| dc.citation.number | 10 | - |
| dc.citation.startPage | 707 | - |
| dc.citation.endPage | 713 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002271038 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | No-linearity error Repeatability error | - |
| dc.subject.keywordAuthor | Rated output | - |
| dc.subject.keywordAuthor | Strain gage | - |
| dc.subject.keywordAuthor | Three-axis force sensor | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.