| dc.description.abstract | This paper describes the design and fabrication of a three-axis force sensor with parallel plate beams (PPSs) for measuring the calf force while a patient with a walking assist robot is walking. Current walking assist robots can’t measure the weight of the patient’s legand the robot’s leg which required for robot control. So, the three-axis force sensor in the calf link is designed and manufactured, it iscomposed of a Fx force sensor, a Fy force sensor and a Fz force sensor. The three-axis force sensor was designed using by FEM(FiniteElement Method), and fabricated using strain-gages. The characteristics experiment of the three-axis force sensor was carried out respec-tively. The test results indicated that the repeatability error and the non-linearity error of three-axis force sensor was less than 0.04% respectively. Therefore, the fabricated three-axis force sensor in the calf link can be used to measure the patient’s calf force in the walking assist robot. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국센서학회 | - |
| dc.title | 다리 환자를 위한 보행보조로봇의 종아리 링크 3축 힘센서 개발 | - |
| dc.title.alternative | Development of Calf Link Force Sensors of Walking Assist Robot for Leg Patients | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5369/JSST.2017.26.2.114 | - |
| dc.identifier.bibliographicCitation | 센서학회지, v.26, no.2, pp 114 - 121 | - |
| dc.citation.title | 센서학회지 | - |
| dc.citation.volume | 26 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 114 | - |
| dc.citation.endPage | 121 | - |
| dc.identifier.kciid | ART002213366 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Gas Strain-gage | - |
| dc.subject.keywordAuthor | Three-axis force sensor | - |
| dc.subject.keywordAuthor | Force sensor | - |
| dc.subject.keywordAuthor | Rated output | - |
| dc.subject.keywordAuthor | Repeatability error | - |
| dc.subject.keywordAuthor | Non-linearity error | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.