Detailed Information

Cited 16 time in webofscience Cited 19 time in scopus
Metadata Downloads

Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters

Authors
Kim, Ji EunKim, Hyun OkBae, KyungsooCho, Jae MinChoi, Ho CheolChoi, Dae Seob
Issue Date
Jul-2017
Publisher
ELSEVIER IRELAND LTD
Keywords
Intrahepatic cholangiocarcinoma; Liver abscess; Computed tomography; Dual-energy; Quantitative evaluation
Citation
EUROPEAN JOURNAL OF RADIOLOGY, v.92, pp.145 - 152
Indexed
SCIE
SCOPUS
Journal Title
EUROPEAN JOURNAL OF RADIOLOGY
Volume
92
Start Page
145
End Page
152
URI
https://scholarworks.bwise.kr/gnu/handle/sw.gnu/13648
DOI
10.1016/j.ejrad.2017.05.012
ISSN
0720-048X
Abstract
Purpose: To investigate the use of dual source dual-energy CT (DECT) quantitative parameters compared with the use of conventional CT for differentiating small (= 3 cm) intrahepatic mass-forming cholangiocarcinoma (IMCC) from small liver abscess (LA) during the portal venous phase (PVP). Material and methods: In this institutional review board-approved, retrospective study, 64 patients with IMCCs and 52 patients with LAs who were imaged in PVP using dual-energy mode were included retrospectively. A radiologist drew circular regions of interest in the lesion on the virtual monochromatic images (VMI), colorcoded iodine overlay images, and linear blending images with a linear blending ratio of 0.3 to obtain CT value, its standard deviation, slope (k) of spectral curve and normalized iodine concentration (NIC). Two radiologists assessed lesion type on the basis of qualitative CT imaging features. Results: CT values on VMI at 50-130 keV (20 keV-interval), k, and NIC values were significantly higher in IMCCs than in LAs (p < 0.0001). The best single parameter for differentiating IMCC from LA was CT value at 90 keV, with sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 89.1%, 86.5%, 87.9%, 89.1%, and 86.5%, respectively. The best combination of parameters was CT value at 90 keV, k, and NIC, with values of 87.5%, 84.6%, 83.6%, 87.5%, and 84.6%, respectively. Compared with CT value at linear blending images, CT value at 90 keV showed greater sensitivity (89.1% vs 60.9%, p < 0.0001) and similar specificity (86.5% vs 84.6%, p= 1.0000), and combined CT value at 90 keV, k, and NIC showed greater sensitivity (87.5% vs 60.9%, p < 0.0001) and similar specificity (84.6% vs 84.6%, p= 1.0000). Compared with qualitative analysis, CT value at 90 keV showed greater sensitivity (89.1% vs 65.6%, p= 0.0059) and specificity (86.5% vs 69.2%, p = 0.0352), and combined CT value at 90 keV, k, and NIC showed greater sensitivity (87.5% vs 65.6%, p= 0.0094) and similar specificity (84.6% vs 69.2%, p> 0.05). Conclusion: Quantitative analysis of dual source dual-energy CT quantitative parameters showed greater accuracy than quantitative and qualitative analyses of conventional CT for differentiating small IMCCs from small LAs on single PVP scan.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Dae Seob photo

Choi, Dae Seob
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE