Cited 26 time in
Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Ji Eun | - |
| dc.contributor.author | Kim, Hyun Ok | - |
| dc.contributor.author | Bae, Kyungsoo | - |
| dc.contributor.author | Cho, Jae Min | - |
| dc.contributor.author | Choi, Ho Cheol | - |
| dc.contributor.author | Choi, Dae Seob | - |
| dc.date.accessioned | 2022-12-26T18:35:45Z | - |
| dc.date.available | 2022-12-26T18:35:45Z | - |
| dc.date.issued | 2017-07 | - |
| dc.identifier.issn | 0720-048X | - |
| dc.identifier.issn | 1872-7727 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/13648 | - |
| dc.description.abstract | Purpose: To investigate the use of dual source dual-energy CT (DECT) quantitative parameters compared with the use of conventional CT for differentiating small (= 3 cm) intrahepatic mass-forming cholangiocarcinoma (IMCC) from small liver abscess (LA) during the portal venous phase (PVP). Material and methods: In this institutional review board-approved, retrospective study, 64 patients with IMCCs and 52 patients with LAs who were imaged in PVP using dual-energy mode were included retrospectively. A radiologist drew circular regions of interest in the lesion on the virtual monochromatic images (VMI), colorcoded iodine overlay images, and linear blending images with a linear blending ratio of 0.3 to obtain CT value, its standard deviation, slope (k) of spectral curve and normalized iodine concentration (NIC). Two radiologists assessed lesion type on the basis of qualitative CT imaging features. Results: CT values on VMI at 50-130 keV (20 keV-interval), k, and NIC values were significantly higher in IMCCs than in LAs (p < 0.0001). The best single parameter for differentiating IMCC from LA was CT value at 90 keV, with sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 89.1%, 86.5%, 87.9%, 89.1%, and 86.5%, respectively. The best combination of parameters was CT value at 90 keV, k, and NIC, with values of 87.5%, 84.6%, 83.6%, 87.5%, and 84.6%, respectively. Compared with CT value at linear blending images, CT value at 90 keV showed greater sensitivity (89.1% vs 60.9%, p < 0.0001) and similar specificity (86.5% vs 84.6%, p= 1.0000), and combined CT value at 90 keV, k, and NIC showed greater sensitivity (87.5% vs 60.9%, p < 0.0001) and similar specificity (84.6% vs 84.6%, p= 1.0000). Compared with qualitative analysis, CT value at 90 keV showed greater sensitivity (89.1% vs 65.6%, p= 0.0059) and specificity (86.5% vs 69.2%, p = 0.0352), and combined CT value at 90 keV, k, and NIC showed greater sensitivity (87.5% vs 65.6%, p= 0.0094) and similar specificity (84.6% vs 69.2%, p> 0.05). Conclusion: Quantitative analysis of dual source dual-energy CT quantitative parameters showed greater accuracy than quantitative and qualitative analyses of conventional CT for differentiating small IMCCs from small LAs on single PVP scan. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters | - |
| dc.type | Article | - |
| dc.publisher.location | 아일랜드 | - |
| dc.identifier.doi | 10.1016/j.ejrad.2017.05.012 | - |
| dc.identifier.scopusid | 2-s2.0-85019381437 | - |
| dc.identifier.wosid | 000405361300020 | - |
| dc.identifier.bibliographicCitation | European Journal of Radiology, v.92, pp 145 - 152 | - |
| dc.citation.title | European Journal of Radiology | - |
| dc.citation.volume | 92 | - |
| dc.citation.startPage | 145 | - |
| dc.citation.endPage | 152 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | HEPATIC-ABSCESSES | - |
| dc.subject.keywordPlus | DYNAMIC CT | - |
| dc.subject.keywordPlus | PERIPHERAL CHOLANGIOCARCINOMA | - |
| dc.subject.keywordPlus | HEPATOCELLULAR-CARCINOMA | - |
| dc.subject.keywordPlus | PATHOLOGICAL CORRELATION | - |
| dc.subject.keywordPlus | ENHANCEMENT PATTERNS | - |
| dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
| dc.subject.keywordPlus | IMAGING FINDINGS | - |
| dc.subject.keywordPlus | FILTRATION | - |
| dc.subject.keywordPlus | QUALITY | - |
| dc.subject.keywordAuthor | Intrahepatic cholangiocarcinoma | - |
| dc.subject.keywordAuthor | Liver abscess | - |
| dc.subject.keywordAuthor | Computed tomography | - |
| dc.subject.keywordAuthor | Dual-energy | - |
| dc.subject.keywordAuthor | Quantitative evaluation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
