Cited 4 time in
Design and fabrication of wearable walking assist robot using tendon-driven method
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Choi, C.-H. | - |
| dc.contributor.author | Kim, G.S. | - |
| dc.date.accessioned | 2022-12-26T18:16:44Z | - |
| dc.date.available | 2022-12-26T18:16:44Z | - |
| dc.date.issued | 2018 | - |
| dc.identifier.issn | 1225-9071 | - |
| dc.identifier.issn | 2287-8769 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/13111 | - |
| dc.description.abstract | In this paper, we design and fabricate a wearable walking-assist robot using a tendon-driven method. Most wearable walking-assist robots are designed using the method of the attaching of the motors to the hip, knee, and ankle joints. The robot needs the capacities of the motors attached to the hip and knee joints to equal the weights of the motors attached to the knee and ankle joints and the motor attached to the ankle, respectively. To solve these problems, we design and fabricate the wearable walking-assist robot using a tendon-driven method that rotates the joints by attaching the motors of the hip, knee, and ankle joints to the waist joint, and pulling it with a line. The gait patterns of a normal person are photographed and analyzed, thereby providing the ankle position (x, y) during the walking that is then calculated using the forward kinematic equation, while each joint angle is calculated using the inverse kinematic equation. As a result of the characteristic experiment of the wearable walking-assist robot, the resultant walking aspect is similar to that of the normal person. Copyright ? 2018 The Korean Society for Precision Engineering. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | Korean Society for Precision Engineeing | - |
| dc.title | Design and fabrication of wearable walking assist robot using tendon-driven method | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.7736/KSPE.2018.35.9.861 | - |
| dc.identifier.scopusid | 2-s2.0-85052754244 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Society for Precision Engineering, v.35, no.9, pp 861 - 866 | - |
| dc.citation.title | Journal of the Korean Society for Precision Engineering | - |
| dc.citation.volume | 35 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 861 | - |
| dc.citation.endPage | 866 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002379537 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Ankle joint | - |
| dc.subject.keywordAuthor | Hip joint | - |
| dc.subject.keywordAuthor | Knee joint | - |
| dc.subject.keywordAuthor | Tendon-driven method | - |
| dc.subject.keywordAuthor | Wearable walking assist robot | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.