8kW급 디젤발전기 소음기 내부 유동에 관한 수치해석open accessNumerical analysis of the Internal Flow of 8kW Grade Diesel Generator Muffler
- Other Titles
- Numerical analysis of the Internal Flow of 8kW Grade Diesel Generator Muffler
- Authors
- 이중섭; 이태의; 이치우
- Issue Date
- 2018
- Publisher
- 한국기계가공학회
- Keywords
- Diesel Generator(디젤발전기); Muffler(소음기); Numerical Analysis(수치해석)
- Citation
- 한국기계가공학회지, v.17, no.3, pp 45 - 50
- Pages
- 6
- Indexed
- KCI
- Journal Title
- 한국기계가공학회지
- Volume
- 17
- Number
- 3
- Start Page
- 45
- End Page
- 50
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/12181
- DOI
- 10.14775/ksmpe.2018.17.3.045
- ISSN
- 1598-6721
2288-0771
- Abstract
- From the flow analysis of the silencer for 8 kW diesel generators, the following results were obtained. For silencer-1, it was confirmed that the holes formed at the inlet-side portion connect into the exhaust pipe in the chamber. The exhaust pipe installed inside silencer-1 was integrally connected through the holes in the chamber. As a result, it was confirmed that the pressure inside the chamber was kept stable. It was confirmed that the pressure loss generated inside an absorptive type silencer such as silencer-2 was small. The differential pressure of the inlet-outlet of silencer-1 and silencer-2 was confirmed to be 494 Pa at 15 m/s, 859 Pa at 20 m/s, 1326 Pa at 25 m/s, and 1911 Pa at 30 m/s.