Design of two-axis force/torque sensor for hip joint rehabilitation robot

Citations

SCOPUS

5

초록

We describe the design and fabrication of a two-axis force/torque sensor with parallel-plate beams (PPBs) and single beams for measuring force and torque in hip-joint rehabilitation exercise using a lower rehabilitation robot. The two-axis force/torque sensor is composed of an Fz force sensor and a Tz torque sensor, which detect z direction force and z direction torque, respectively. The two-axis force/torque sensor was designed using the FEM (Finite Element Method) and manufactured using strain gages. The characteristics experiment of the two-axis force/torque sensor was carried out. The test results show that the interference error of the two-axis force/torque sensor was less than 0.64% and the repeatability error and the non-linearity of the two-axis force/torque sensor were less than 0.03%. It is thought that the developed two-axis force/torque sensor could be used for a lower rehabilitation robot. ? ICROS 2016.

키워드

Hip-joint rehabilitation; Interference error; Nolinearity error; Rated output; Repeatability error; Strain gage; Two-axis force/torque sensor
제목
Design of two-axis force/torque sensor for hip joint rehabilitation robot
저자
Kim, H.-S.; Kim, G.-S.
DOI
10.5302/J.ICROS.2016.16.0067
발행일
2016
유형
Article
저널명
제어.로봇.시스템학회 논문지
권
22
호
7
페이지
524 ~ 529