Detailed Information

Cited 40 time in webofscience Cited 47 time in scopus
Metadata Downloads

Efficacy of Assessing Intraoperative Bowel Perfusion with Near-Infrared Camera in Laparoscopic Gastric Cancer Surgery

Authors
Huh, Yeon-JuLee, Hyuk-JoonKim, Tae-HanChoi, Yun-suckPark, Ji-HoSon, Young-GilSuh, Yun-SuhkKong, Seong-HoYang, Han-Kwang
Issue Date
1-Apr-2019
Publisher
MARY ANN LIEBERT, INC
Keywords
indocyanine green; perfusion; stomach neoplasm; laparoscopic gastrectomy
Citation
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, v.29, no.4, pp 476 - 483
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES
Volume
29
Number
4
Start Page
476
End Page
483
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/9249
DOI
10.1089/lap.2018.0263
ISSN
1092-6429
1557-9034
Abstract
Background: Anastomotic leakage is a severe complication after gastric cancer surgery. Inadequate blood supply is regarded as an important risk factor. The aim of the study was to evaluate the feasibility and usefulness of intraoperative assessment of anastomotic vascular perfusion in gastric cancer surgery using near-infrared (NIR) camera imaging with indocyanine green (ICG)-enhanced fluorescence technique. Materials and Methods: From March 2015 to 2016, 30 patients undergoing laparoscopic gastrectomy for gastric cancer were prospectively evaluated. After completing the anastomosis, 2.5-5.0 mg of ICG was injected via peripheral veins. All anastomoses and resection margins were investigated using NIR camera to assess anastomotic perfusion. The assessment was performed using the adopted perfusion score of fluorescence activity, which ranged from 1 to 5 (1 = no uptake, and 5 = iso-fluorescent to all other segments). Results: Twenty-six distal gastrectomy (20 gastroduodenostomies, 6 gastrojejunostomies), 3 total gastrectomies (TG), and 1 pylorus-preserving gastrectomy were performed. The gap of visualization was 4.1 +/- 3.2 minutes (range, 2-15) after ICG injection. Twenty-three of 30 patients (76.7%) showed technically successful ICG visualization. Among gastroduodenostomies, the average scores for gastric and duodenal sides were 3.5 and 3.7. Among gastrojejunostomies, the average scores for gastric, jejunal, and duodenal stump sides were 3.5, 4.0, and 3.8 (jejunojejunostomy, 3.5). Among TG, the average scores for esophagojejunostomy, duodenal stump, and jejunojejunostomy were 3.7, 4.0, 4.0, and 4.7. One case of leakage occurred in this study. Other complications included fluid collection and stenosis in 1 patient each. Conclusions: This study showed intraoperative ICG angiography using NIR camera is feasible and provides imaging of anastomotic blood flow. Further studies are needed for practice.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE