Detailed Information

Cited 20 time in webofscience Cited 22 time in scopus
Metadata Downloads

Mechanical effect of different implant caput-collum-diaphyseal angles on the fracture surface after fixation of an unstable intertrochanteric fracture: A finite element analysisopen access

Authors
Kim, Jung-TaekJung, Chang-HoShen, Quan HuCha, Yong-HanPark, Chan HoYoo, Jun-IlSong, Hyung KeunJeon, YonghoWon, Ye-Yeon
Issue Date
Nov-2019
Publisher
Elsevier Taiwan
Keywords
Hip fracture; Fracture fixation; Proximal femoral nail antirotation; Finite element analysis
Citation
Asian Journal of Surgery, v.42, no.11, pp 947 - 956
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
Asian Journal of Surgery
Volume
42
Number
11
Start Page
947
End Page
956
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/8594
DOI
10.1016/j.asjsur.2019.01.008
ISSN
1015-9584
0219-3108
Abstract
Background/Objective: The choice of implant is one of the most easily controllable factors affecting the outcome of intertrochanteric fractures. While most of the caputcollum-diaphysis (CCD) angles of the femur are within the range of 125 degrees and 130 degrees, there is a shortage of data on whether 125 degrees or 130 degrees implants are preferable. Thus, the present finite element analysis (FEA) aimed to compare the biomechanical effects on the fracture surface when using implants with different CCD angles where the anatomical CCD angle of the femur was between 125 degrees and 130 degrees. Methods: After establishing a finite element model of an unstable intertrochanteric fracture from the femur with a native CCD angle of 127.3 degrees, proximal femoral nail antirotation (PFNA) models with CCD angles of 125 degrees and 130 degrees were virtually implanted to have the same position of screw tip, respectively. Results: In the one-leg stance during walking, when the implant with 130 degrees CCD angle was used, the magnitude of compressive stress (1.61 and 2.12 MPa in the 130 degrees and 125 degrees model, respectively) was lower and the area of the fracture surface under tensile stress (55% and 5% in 130 degrees and 125 degrees model, respectively), the interfragmentary movements (40.9% more movement in 130 degrees model), and the magnitude of bone deformation (23.5% more deformation in 130 degrees model) were more than those of the 125 degrees model. Conclusion: The intertrochanteric fracture fixed with PFNA with a 125 degrees CCD angle revealed less interfragmentary movement on the fracture surface when the native CCD was an in-between angle in the FEA. (C) 2019 Asian Surgical Association and Taiwan Robotic Surgery Association. Publishing services by Elsevier B.V.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE