Performance evaluation of commercial ion-selective electrodes for hydroponic cultivation system
- Authors
- Chowdhury, M.; Jang, B.E.; Kabir, M.S.N.; Lee, D.H.; Kim, H.T.; Park, T.S.; Chung, S.O.
- Issue Date
- 23-Nov-2020
- Publisher
- International Society for Horticultural Science
- Keywords
- Hydroponics; Ion-selective electrodes; Nutrient ions sensing; Sensing errors
- Citation
- Acta Horticulturae, v.1296, pp 831 - 838
- Pages
- 8
- Indexed
- SCOPUS
- Journal Title
- Acta Horticulturae
- Volume
- 1296
- Start Page
- 831
- End Page
- 838
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/8272
- DOI
- 10.17660/ActaHortic.2020.1296.105
- ISSN
- 0567-7572
- Abstract
- The performance evaluation of commercial ion-selective electrodes (ISE) is important for real-time, ion-based nutrient management in hydroponic crop cultivation systems as the fabrication, ion-sensing membrane’s composition and contamination, storage duration, ion interference, use time, and solution types of ISE cause sensing errors. In this research, the performance of K+, NO3-, and Ca2+ ion-selective electrodes were evaluated in regard to measurement error, potential drift, and calibration for building an effective nutrient management system. A recycle-type aeroponic nutrient management test bench was designed and fabricated. The K+, NO3-, and Ca2+ ISE were attached and tested in the ion-sensing chamber of that test bench. A LabVIEW-coded program and NI-DAQ device were used for data collection. The measurement error percentage was checked in five different levels of nutrient solution. ISE sensors were immersed into a known nutrient level solution for 15 days to check the potential drift trends, and a two-point calibration technique was applied to minimize error effects. A linear relationship was found while testing the measurement error of K+, NO3-, and Ca2+ ISE in five different levels of nutrient solution, where R2 and RMSE were 0.98, 36.86 ppm; 0.99, 22.25 ppm, and 0.99, 12.94 ppm, respectively. The ISE showed continuous upward (R2=0.94, RMSE=54.66 ppm), upward (R2=0.85, RMSE=1.24 ppm), and downward (R2=0.86, RMSE=4.53 ppm) potential drifts, respectively. Two-point calibration to reduce errors showed R2 values of 0.99, 0.99 and 0.99 for K+, NO3-, and Ca2+ ISE, respectively. These results indicated that the performance of commercial ISE needs to be evaluated for improved real-time nutrient ion monitoring in hydroponic cultivation systems. ? 2020 International Society for Horticultural Science. All rights reserved.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 농업생명과학대학 > 생물산업기계공학과 > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.