Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Enhancing Robustness in Gastroscopy Analysis With Poisson–Gaussian Noise-Based Adversarial Augmentationopen access

Authors
Kim, Ji-HwanChae, Jung-WooChin Cho, HyunCho, Hyun-Chong
Issue Date
Nov-2025
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Computer-aided diagnosis (CADx); gastric cancer; gastroscopy; imperceptible perturbation; Poisson-Gaussian noise-based adversarial augmentation (PGAA)
Citation
IEEE Access, v.13, pp 192391 - 192402
Pages
12
Indexed
SCIE
SCOPUS
Journal Title
IEEE Access
Volume
13
Start Page
192391
End Page
192402
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/81233
DOI
10.1109/ACCESS.2025.3631278
ISSN
2169-3536
2169-3536
Abstract
Gastroscopy is a key diagnostic procedure for gastric cancer, but its image quality is often degraded by complex noise from illumination, anatomy, and device variability, which can impair computer-aided diagnosis (CADx) systems. To address these challenges, we propose a Poisson-Gaussian noise-based Adversarial Augmentation (PGAA) method that simulates realistic photon-limited and sensor-readout noise through imperceptible perturbations, improving model robustness against clinically relevant noise. An accompanying Adaptive Weight Normalization (AWN) mechanism adaptively scales perturbations according to local noise sensitivity, preserving lesion boundaries and mucosal textures. To ensure a fair and comprehensive comparison, experiments were conducted using both single-step Fast Gradient Sign Method (FGSM) and iterative Projected Gradient Descent (PGD) adversarial perturbations, as well as across different backbone networks, including ConvNeXt V2-B. PGD was adopted as a theoretically consistent and stronger baseline to verify robustness beyond simple gradient-based attacks. Results on both in-house and public datasets demonstrated consistent improvements across recall, accuracy, F1-score, and AUC metrics. On the in-house dataset, the proposed PGAA-AWN achieved an AUC of 95.5%, with improvements of up to 2.4% in recall, 4.9% in accuracy, and 4.3% in F1-score over the baseline, while also showing the highest performance on the public Kvasir dataset. Although optimized for gastroscopy, the proposed frameworks are modality-agnostic and can be extended to other noise-prone medical imaging modalities such as CT, MRI, and X-ray, contributing to the development of robust and interpretable medical AI systems. © 2013 IEEE.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher ,  photo

,
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE