A probe-corrected loop-mediated isothermal amplification–lateral flow assay platform for highly specific, point-of-care detection of Brucella abortus DNA
- Authors
- Lee, Jeong-Eun; Cho, Yong Sun; Mun, Hyoyoung; Kim, Hyun-Jin; Kim, Suk; Shim, Won-Bo
- Issue Date
- Dec-2025
- Publisher
- Elsevier BV
- Keywords
- Biotinylated probe; Brucella abortus; False-positive discrimination; LAMP; LFA
- Citation
- Microchemical Journal, v.219
- Indexed
- SCIE
SCOPUS
- Journal Title
- Microchemical Journal
- Volume
- 219
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/81073
- DOI
- 10.1016/j.microc.2025.116153
- ISSN
- 0026-265X
1095-9149
- Abstract
- Brucellosis, primarily caused by Brucella abortus, is a significant zoonotic disease affecting cattle worldwide. Accurate and early detection of B. abortus is crucial for effective disease control; however, existing diagnostic methods are limited by low sensitivity, lengthy processing times, and impracticality for field use. In this study, we developed a novel loop-mediated isothermal amplification–lateral flow assay (LAMP–LFA) platform that integrates a biotinylated DNA probe and fluorescein isothiocyanate–labeled primers to detect BruAb2_0168 of B. abortus. Unlike conventional LAMP-based diagnostics, our platform does not entirely prevent nonspecific amplification. Instead, it distinguishes target-specific products from nonspecific products by selective probe hybridization. Only true-positive amplicons hybridize with the probe to produce visible signals on the LFA strip, effectively eliminating the false-positive interpretations that typically limit the diagnostic reliability of LAMP-based methods. We optimized the amplification conditions (temperature, time, and primer/probe concentration) and LFA strip design to ensure high performance. Our platform achieved a detection limit of ≥8.85 CFU/mL, and no cross-reactivity was observed with other common pathogens. Validation using 20 whole-blood samples demonstrated that its diagnostic performance was statistically equivalent to that of polymerase chain reaction (area under the curve = 1.0, McNemar's p > 0.05). The assay reports results within 1 h, requires no instrumentation, and is suitable for use in field or resource-limited settings. Overall, our probe-corrected LAMP–LFA platform offers enhanced specificity, operational simplicity, and field-deployable utility, making it a valuable alternative for rapid and accurate B. abortus diagnosis. © 2024
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 농업생명과학대학 > 식품공학부 > Journal Articles
- 수의과대학 > Department of Veterinary Medicine > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.