Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

양안의 적도부 및 뒤섬모체소대약화가 관찰된 백내장 증례보고A Case of a Cataract Patient with Equatorial and Posterior Zonular Weakness in Both Eyes

Other Titles
A Case of a Cataract Patient with Equatorial and Posterior Zonular Weakness in Both Eyes
Authors
Kwon, Jeong WooJeong, In SeokChung, In YoungSeo, Seong WookKim, Seong Jae
Issue Date
Apr-2025
Publisher
대한안과학회
Keywords
Capsulorhexis; Cataract; Posterior capsulotomy; Vitrectomy
Citation
대한안과학회지, v.66, no.4, pp 209 - 213
Pages
5
Indexed
SCOPUS
ESCI
KCI
Journal Title
대한안과학회지
Volume
66
Number
4
Start Page
209
End Page
213
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/77876
DOI
10.3341/jkos.2025.66.4.209
ISSN
0378-6471
2092-9374
Abstract
Purpose: We present a case of equatorial and posterior zonular weakness observed during cataract surgery in both eyes with no prior history of trauma or surgery. Case summary: A 73-year-old woman visited out clinic and reported decreased visual acuity. She was found to have a best corrected visual acuity of 0.5 in both eyes. Cataracts were noted during a slit lamp examination and cataract surgery was subsequently performed. During the left eye surgery, although there was no evident weakening during the anterior capsulotomy, the equatorial and posterior zonules were damaged during phacoemulsification. This led to consistent aspiration of the equatorial and posterior capsule (PC) into the phaco-handpiece tip during epinucleus and cortex removal. The PC eventually ruptured necessitating anterior vitrectomy and a 3-piece intraocular lens insertion into the ciliary sulcus. Two weeks later, the right eye surgery encountered similar challenges in removing the epinucleus and cortex. The surgery was completed successfully by elevating the irrigation bottle, frequently injecting an ophthalmic viscoelastic device (OVD), and removing the remaining lens material using a bimanual irrigator/aspirator. Conclusions: This case highlights that equatorial and posterior zonular weakness can occur in the absence of trauma or prior to surgery. To manage such cases, it is advisable to elevate the irrigation bottle height, continuously inject OVD during surgery, and use a bimanual irrigator/aspirator. © 2025 The Korean Ophthalmological Society.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles
의학계열 > 의학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Seong Wook photo

Seo, Seong Wook
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE