Artificial intelligence applied to electrocardiogram to rule out acute myocardial infarction: the ROMIAE multicentre study

Authors
Lee, Min SungShin, Tae GunLee, YoungjooKim, Dong HoonChoi, Sung HyukCho, HanjinLee, Mi JinJeong, Ki YoungKim, Won YoungMin, Young GiHan, ChulYoon, Jae CholJung, EujeneKim, Woo JeongAhn, ChiwonSeo, Jeong YeolLim, Tae HoKim, Jae SeongChoi, JeffKwon, Joon-myoungKim, Kyuseok
Issue Date
May-2025
Publisher
Oxford University Press
Keywords
Acute myocardial infarction; Artificial intelligence; Electrocardiogram; Emergency department; Acute coronary syndrome; AI/ML-enabled SaMD
Citation
European Heart Journal, v.46, no.20, pp 1917 - 1929
Pages
13
Indexed
SCIE
SCOPUS
Journal Title
European Heart Journal
Volume
46
Number
20
Start Page
1917
End Page
1929
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/77387
DOI
10.1093/eurheartj/ehaf004
ISSN
0195-668X
1522-9645
Abstract
Background and Aims Emerging evidence supports artificial intelligence-enhanced electrocardiogram (AI-ECG) for detecting acute myocardial infarction (AMI), but real-world validation is needed. The aim of this study was to evaluate the performance of AI-ECG in detecting AMI in the emergency department (ED).Methods The Rule-Out acute Myocardial Infarction using Artificial intelligence Electrocardiogram analysis (ROMIAE) study is a prospective cohort study conducted in the Republic of Korea from March 2022 to October 2023, involving 18 university-level teaching hospitals. Adult patients presenting to the ED within 24 h of symptom onset concerning for AMI were assessed. Exposure included AI-ECG score, HEART score, GRACE 2.0 score, high-sensitivity troponin level, and Physician AMI score. The primary outcome was diagnosis of AMI during index admission, and the secondary outcome was 30 day major adverse cardiovascular event (MACE).Results The study population comprised 8493 adults, of whom 1586 (18.6%) were diagnosed with AMI. The area under the receiver operating characteristic curve for AI-ECG was 0.878 (95% CI, 0.868-0.888), comparable with the HEART score (0.877; 95% CI, 0.869-0.886) and superior to the GRACE 2.0 score, high-sensitivity troponin level, and Physician AMI score. For predicting 30 day MACE, AI-ECG (area under the receiver operating characteristic, 0.866; 95% CI, 0.856-0.877) performed comparably with the HEART score (0.858; 95% CI, 0.848-0.868). The integration of the AI-ECG improved risk stratification and AMI discrimination, with a net reclassification improvement of 19.6% (95% CI, 17.38-21.89) and a C-index of 0.926 (95% CI, 0.919-0.933), compared with the HEART score alone.Conclusions In this multicentre prospective study, the AI-ECG demonstrated diagnostic accuracy and predictive power for AMI and 30 day MACE, which was similar to or better than that of traditional risk stratification methods and ED physicians.