Application and evaluation knitted electrodes for body signal measurement using adhesive intermediate electrodeopen accessApplication and evaluation knitted electrodes for body signal measurement using adhesive intermediate electrode
- Other Titles
- Application and evaluation knitted electrodes for body signal measurement using adhesive intermediate electrode
- Authors
- Song, Ji Eun; Lee, Sohee
- Issue Date
- Nov-2024
- Publisher
- 한국의류학회
- Keywords
- Bio signal; Electronic textiles; Knitted electrode; Knitting; Smart textile; Surface electromyography; Textile electrode
- Citation
- Fashion and Textiles, v.11, no.1, pp 1 - 15
- Pages
- 15
- Indexed
- SCIE
SCOPUS
KCI
- Journal Title
- Fashion and Textiles
- Volume
- 11
- Number
- 1
- Start Page
- 1
- End Page
- 15
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/74851
- DOI
- 10.1186/s40691-024-00404-9
- ISSN
- 2198-0802
2198-0802
- Abstract
- Textile electrode is capable of measuring the myoelectric potentials of skeletal muscles such as electromyography (EMG), owing to their outstanding low weight, flexibility, breathability, and comfort properties. Nonetheless, textile surfaces often exhibit intermittent adhesion between the electrode surface and the skin, which can result in fluctuations in electrical resistivity due to the inherent characteristics of textiles. This study aimed to suggest the solutions to improve adhesive of textile electrode for the improvement of electrode performance with high quality signal by minimizing these intermittent contacts. For this, an adhesive intermediate, two different conductive materials, between the skin and the textile electrode was introduced to improve the instability skin contact, respectively. To assess the impact of various adhesive intermediates on knitted electrodes, two different types of adhesive intermediates were utilized: a conductive hydrogel-based adhesive intermediate and a conductive paste-based adhesive intermediate. Moreover, the durability of knitted electrodes with adhesive intermediate was evaluated by assessing the changes of signal quality during drying time for 180 min. As a results of sEMG measurement, it was confirmed that the sEMG signal was stably detecting by applying the adhesive intermediate. Both types of adhesive intermediate significantly increased the signal acquisition performance of knitted electrodes by more than threefold. After five washing cycle, the knitted electrodes with two types of adhesive intermediate maintained approximately 80% of their initial SNR values. Therefore, the use of the adhesive intermediate presented in this study not only improves the performance of the electrode but also ensures reusability. © The Author(s) 2024.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 자연과학대학 > 의류학과 > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.