Detailed Information

Cited 1 time in webofscience Cited 2 time in scopus
Metadata Downloads

Clinical usability and efficacy of a robotic bone fracture reduction system: A pilot animal study

Authors
Bang, HyunheeLee, Hyun-JooLee, Suk-JoongJoung, SanghyunKim, Joon-WooOh, Chang-wugPark, Il-Hyung
Issue Date
Nov-2024
Publisher
Elsevier Ltd
Keywords
Bovine model; Fracture reduction; Long bone fracture; Malrotation; Radiation exposure; Robotic surgery
Citation
Medical Engineering and Physics, v.133
Indexed
SCIE
SCOPUS
Journal Title
Medical Engineering and Physics
Volume
133
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/74752
DOI
10.1016/j.medengphy.2024.104242
ISSN
1350-4533
1873-4030
Abstract
Challenges in minimally invasive surgeries, such as intramedullary nailing for long bone fractures, include radiation overexposure for patients and surgeons, potential malreduction, and physical burden on surgeons in maintaining the reduction status. A robotic bone fracture reduction system was developed in this study to address these problems. The system consists of a hexapod with six degrees of freedom, with a fracture reduction device and a master device. This study aimed to evaluate the novel system in a preclinical setting. The length of the six axes in the system can be adjusted to precisely control the length, angle, and rotation so that no additional traction is required. Fluoroscopic images can be remotely examined to reduce the risk of radiation exposure for surgeons. In this study, alignment accuracy and radiation exposure were measured using 32 bovine bone fracture models, and these surgical outcomes were compared to those of conventional manual surgery to verify the clinical usability and effectiveness of the system. The alignment accuracy was assessed by analyzing length, angulation, and rotation. The four surgeons participating in this study were divided into two groups (expert and novice) according to their clinical experience. All parameters in robotic surgery significantly decreased by approximately 4 mm and 8° on average (p ≤ 0.05) compared to conventional surgery. The mean radiation exposure in robot-assisted surgery was 0.11 mSv, showing a significant decrease compared to conventional surgery (p < 0.05). Reduction accuracy was higher in robotic surgery performed by the novice group than in conventional surgery performed by the expert group; however, standard deviation values were inversed. In conclusion, the bone fracture reduction robot system increased the alignment accuracy through precise control while reducing radiation exposure in surgeons, as the surgery was performed remotely. The use of this system is predicted to improve the accuracy and reproducibility of the surgery and the safety of medical staff.1 © 2024 IPEM
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE