Cited 0 time in
자동차용 수소 차단밸브의 열전달 특성에 대한 수치해석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김나용 | - |
| dc.contributor.author | 김문학 | - |
| dc.contributor.author | 이치우 | - |
| dc.date.accessioned | 2024-12-03T07:00:41Z | - |
| dc.date.available | 2024-12-03T07:00:41Z | - |
| dc.date.issued | 2024-10 | - |
| dc.identifier.issn | 1229-604X | - |
| dc.identifier.issn | 2508-3805 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/74588 | - |
| dc.description.abstract | The hydrogen valve used in this study is intended to be applied to a automobile, and since there is a limit to the length of the stem, it is necessary to review the optimized stem, and for this, it is required to investigate the heat transfer characteristics of the hydrogen shut-off valve. For this, the temperature of the entire shut-off valve and especially the plunger and O-ring, which are key components in the solenoid valve driving the hydrogen shut-off valve, was calculated using the ANSYS-CFX flow analysis program. From the analysis results, the length of the stem capable of maintaining the design temperature of -40℃ or higher should be at least 139 mm, and it is judged that it should be 140 mm or more considering safety. When determining the stem length of the hydrogen blocking valve for automobiles, constraints on installation in automobiles should be considered. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계기술학회 | - |
| dc.title | 자동차용 수소 차단밸브의 열전달 특성에 대한 수치해석 | - |
| dc.title.alternative | Numerical Analysis of Heat Transfer Characteristics of Hydrogen Shut-off Valve for Automotive Vehicles | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국기계기술학회지, v.26, no.5, pp 1022 - 1028 | - |
| dc.citation.title | 한국기계기술학회지 | - |
| dc.citation.volume | 26 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 1022 | - |
| dc.citation.endPage | 1028 | - |
| dc.identifier.kciid | ART003130390 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 열전달 | - |
| dc.subject.keywordAuthor | 수소 | - |
| dc.subject.keywordAuthor | 수치해석 | - |
| dc.subject.keywordAuthor | 차단밸브 | - |
| dc.subject.keywordAuthor | 스템 | - |
| dc.subject.keywordAuthor | 온도 | - |
| dc.subject.keywordAuthor | Heat Transfer | - |
| dc.subject.keywordAuthor | Hydrogen | - |
| dc.subject.keywordAuthor | Numerical Analysis | - |
| dc.subject.keywordAuthor | Shut-off Valve | - |
| dc.subject.keywordAuthor | Stem | - |
| dc.subject.keywordAuthor | Temperature | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.