Static analysis-based rapid fire-following earthquake risk assessment method using simple building and GIS informationopen access

Authors
Kang, JaedoKang, TaewookLee, KihakKim, HyewonShin, Jiuk
Issue Date
Sep-2024
Publisher
Nature Research
Keywords
Fire-burned rate; Fire-following earthquake; Fire-spread simulation; Ignition rate
Citation
Scientific Reports, v.14, no.1
Indexed
SCIE
SCOPUS
Journal Title
Scientific Reports
Volume
14
Number
1
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/74472
DOI
10.1038/s41598-024-72363-6
ISSN
2045-2322
2045-2322
Abstract
After the occurrences of large-scale earthquakes, secondary damage (e.g., fire following earthquake) can result in tremendous losses of life, properties, and buildings. To reduce these disaster risks, fire following earthquake assessment methods composed of ignition and fire-burned rate estimation models have been utilized. However, previous methods required for large amounts of building and GIS information, and complex modeling and analysis processes, leading to significant time consumption. This paper proposed a static analysis-based rapid fire following earthquake assessment method using simple information and implemented it in Pohang City, South Korea. Based on previous studies, the best-fit model for the ignition rate estimation was selected, and a cluster-based fire-burned rate estimation model was developed using simple building information (e.g., construction year, building occupancy, story, and total floor area) from the public building database (e.g., building registration data). For the fire-burned rate estimation model, fire-resistant structure types were defined using simple building information, and this was utilized to generate clusters of buildings at a regional level by comparing fire-spread distances for each fire-resistant structure type with adjacent distances among the buildings. This proposed method was applied to Pohang City, South Korea, and validated as follows: (1) the selected ignition rate model predicted similar ignition numbers to the actual reported number (actual number of ignitions = 4 vs. predicted number of ignitions = 3), and (2) the fire-burned rate model estimated fire-burned areas with a marginal difference compared to the fire spread simulation (fire-burned area using the proposed model = 13,703.6 m2 vs. results of fire spread simulation = 16,800.0 m2, with an error of approximately 18%). © The Author(s) 2024.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles
공학계열 > 건축공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Ji Uk photo

Shin, Ji Uk
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE