Detailed Information

Cited 11 time in webofscience Cited 13 time in scopus
Metadata Downloads

Improvement of Gastroscopy Classification Performance Through Image Augmentation Using a Gradient-Weighted Class Activation Mapopen access

Authors
Ham, Hyun-SikLee, Han-SungChae, Jung-WooCho, Hyun ChinCho, Hyun-Chong
Issue Date
Sep-2022
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Cancer; Lesions; Sensitivity; Endoscopes; Deep learning; Convolutional neural networks; Training data; Clinical diagnosis; Image augmentation; Gastrointestinal tract; Class activation map; classification; computer-aided diagnosis (CADx); deep learning; gastroscopy; image augmentation
Citation
IEEE Access, v.10, pp 99361 - 99369
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
IEEE Access
Volume
10
Start Page
99361
End Page
99369
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/71620
DOI
10.1109/ACCESS.2022.3207839
ISSN
2169-3536
2169-3536
Abstract
Endoscopic specialists performing gastroscopy, which relies on the naked eye, may benefit from a computer-aided diagnosis (CADx) system that employs deep learning. This report proposes utilizing a CADx system to classify normal and abnormal gastric cancer, gastritis, and gastric ulcer. The CADx system was trained using a deep learning algorithm known as a convolutional neural network (CNN). Specifically, Xception, which includes depth-wise separable convolution, was employed as the CNN. Image augmentation was applied to improve the disadvantages of medical data, which are difficult to collect. A class activation map (CAM), an algorithm that visualizes the classified region of interest in a CNN, was used to cut and paste the image area into another image. The CAM-identified lesion location in an abnormal image was augmented by pasting it into a normal image. The normal image was divided into nine equal parts and pasted where the variance difference from the lesion was minimal. Consequently, the number of abnormal images increased by 360,905. Xception was used to train the augmented dataset. A confusion matrix was used to evaluate the performance of the gastroscopy CADx system. The performance criteria were specificity, sensitivity, F1 score, harmonic average of precision, sensitivity (recall), and AUC. The F1 score of the CADx system trained with the original dataset was 0.792 and AUC was 0.885. The dataset augmentation approach using CAM presented in this report is shown to be an effective augmentation algorithm, with performance improved to 0.835, 0.903 in terms of F1 score and AUC respectively.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE