Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

유동소음기용 다공성 발포알루미늄에 대한 유동해석CFD Analysis of Porous Foamed Aluminium for Flow Silencer

Other Titles
CFD Analysis of Porous Foamed Aluminium for Flow Silencer
Authors
김나용김봉환
Issue Date
2020
Publisher
한국기계기술학회
Keywords
Flow silencer; Foamed aluminium; Porosity; Porous media; Loss coefficient; Quadratic resistance coefficient; Pressure drop; CFD; 유동소음기; 발포알루미늄; 다공도; 다공성 매질; 손실계수; 2차 저항계수; 압력강하; 전산유체역학
Citation
한국기계기술학회지, v.22, no.5, pp.845 - 851
Indexed
KCI
Journal Title
한국기계기술학회지
Volume
22
Number
5
Start Page
845
End Page
851
URI
https://scholarworks.bwise.kr/gnu/handle/sw.gnu/7155
DOI
10.17958/ksmt.22.5.202010.845
ISSN
1229-604X
Abstract
There are many disadvantages to existing silencers used in power plants. Recently, high-performance silencers are required in society, so it is necessary to develop silencers accordingly. Therefore, in this study, to develop the flow silencer by taking advantage of the foamed aluminum, the property values such as loss coefficient and porosity were obtained through experiments, based on the Forchheimer's law. CFD analysis was performed by applying a porous modeling technique to foamed aluminum and the results were compared with experimental values. The error rate between the results of the experiment and the flow analysis is within about 2.79%, so the results of the experiment and the analysis agree relatively well. When the foamed aluminum was installed, the flow noise was reduced by about 5.14dB.
Files in This Item
There are no files associated with this item.
Appears in
Collections
융합기술공과대학 > Department of Automotive Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE