Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

최소 환기 조건의 주거공간에서 인플루엔자 바이러스 단기 노출에 따른 공기전파감염확률 분석Airborne Infection Risk of Influenza Virus by Short-Term Exposure in a Residential Space with Minimum Ventilation

Other Titles
Airborne Infection Risk of Influenza Virus by Short-Term Exposure in a Residential Space with Minimum Ventilation
Authors
정창헌
Issue Date
2020
Publisher
한국생활환경학회
Keywords
Airborne infection; Influenza; Short-term exposure; Residential space; Quanta generation
Citation
한국생활환경학회지, v.27, no.5, pp.606 - 615
Indexed
KCI
Journal Title
한국생활환경학회지
Volume
27
Number
5
Start Page
606
End Page
615
URI
https://scholarworks.bwise.kr/gnu/handle/sw.gnu/7151
DOI
10.21086/ksles.2020.10.27.5.606
ISSN
1226-1289
Abstract
This study evaluated the airborne infection risk of influenza virus after 3 hours of exposure in residential space considering different quanta generations, half-life times and fixed ventilation rate of room(0.5 ACH). The concentrations of influenza virus in well-mixed air condition, as input data for airborne infection risks, were calculated by airflow network simulation tool, COMTAMW. The results indicate that under constant ventilation rate of 0.5 ACH, the amount of influenza virus released by normal exhalation(4 quanta/h) and 15 minutes of half-time contribute to limited airborne infection risks of 7.4%. However, if the half-time of influenza virus increses to 1440 minutes (24 hours), infection risk after 3 hours exposures is 23.3%. These results of worst case show that airborne infection risk by the asymptomatic infectious in calm physical state is not safe in slightly ventilated space with 0.5 ACH. Increased quanta generation of influenza virus by cough, sneeze or slight physical activity can result in considerably higher infection risks. Long half-life period of influenza virus also contributes to increased infection risk. Consequently, appropriate solutions should be made to mitigate airborne infection risk of influenza in slightly ventilated residential space.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cheong, Chang Heon photo

Cheong, Chang Heon
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE