Ongoing Laboratory Performance Study on Chemical Analysis of Hydrophobic and Hydrophilic Compounds in Three Aquatic Passive Samplers
- Authors
- Booij, Kees; Crum, Steven; Vrana, Branislav; Grabic, Roman; Morin, Nicolas A. O.; Parmentier, Koen; Kech, Cécile; Krystek, Petra; Noro, Kazushi; Becker, Benjamin; Lohmann, Rainer; Malleret, Laure; Kaserzon, Sarit L.; Miège, Cécile; Alliot, Fabrice; Pfeiffer, Fabienne; Crowley, Denis; Rakowska, Magdalena; Ocelka, Tomas; Kim, Gi Beum; Röhler, Laura
- Issue Date
- Apr-2024
- Publisher
- American Chemical Society
- Keywords
- interlaboratory comparison; passive sampling; POCIS; polyethylene; proficiency testing; quality control; silicone
- Citation
- Environmental Science & Technology, v.58, no.15, pp 6772 - 6780
- Pages
- 9
- Indexed
- SCIE
SCOPUS
- Journal Title
- Environmental Science & Technology
- Volume
- 58
- Number
- 15
- Start Page
- 6772
- End Page
- 6780
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/70286
- DOI
- 10.1021/acs.est.3c10272
- ISSN
- 0013-936X
1520-5851
- Abstract
- The quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program. The median CV over all rounds was 32%. Much higher variabilities were observed for hydrophilic compound concentrations in the sorbent: 50% for the untransformed data and a factor of 1.6 after log transformation. Limiting the data to the best performing laboratories did not result in less variability. Data quality for hydrophilic compounds was only weakly related to the use of structurally identical internal standards and was unrelated to the choice of extraction solvent and extraction time. Standard deviations of the aqueous concentration estimates for hydrophobic compound sampling by the best performing laboratories were 0.21 log units for silicone and 0.27 log units for LDPE (factors of 1.6 to 1.9). The implications are that proficiency testing programs may give more realistic estimates of uncertainties in chemical analysis than within-laboratory quality control programs and that these high uncertainties should be taken into account in environmental assessments. © 2024 American Chemical Society.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 해양과학대학 > Department of Marine Environmental Engineering > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.