Ongoing Laboratory Performance Study on Chemical Analysis of Hydrophobic and Hydrophilic Compounds in Three Aquatic Passive Samplers

Authors
Booij, KeesCrum, StevenVrana, BranislavGrabic, RomanMorin, Nicolas A. O.Parmentier, KoenKech, CécileKrystek, PetraNoro, KazushiBecker, BenjaminLohmann, RainerMalleret, LaureKaserzon, Sarit L.Miège, CécileAlliot, FabricePfeiffer, FabienneCrowley, DenisRakowska, MagdalenaOcelka, TomasKim, Gi BeumRöhler, Laura
Issue Date
Apr-2024
Publisher
American Chemical Society
Keywords
interlaboratory comparison; passive sampling; POCIS; polyethylene; proficiency testing; quality control; silicone
Citation
Environmental Science & Technology, v.58, no.15, pp 6772 - 6780
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
Environmental Science & Technology
Volume
58
Number
15
Start Page
6772
End Page
6780
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/70286
DOI
10.1021/acs.est.3c10272
ISSN
0013-936X
1520-5851
Abstract
The quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program. The median CV over all rounds was 32%. Much higher variabilities were observed for hydrophilic compound concentrations in the sorbent: 50% for the untransformed data and a factor of 1.6 after log transformation. Limiting the data to the best performing laboratories did not result in less variability. Data quality for hydrophilic compounds was only weakly related to the use of structurally identical internal standards and was unrelated to the choice of extraction solvent and extraction time. Standard deviations of the aqueous concentration estimates for hydrophobic compound sampling by the best performing laboratories were 0.21 log units for silicone and 0.27 log units for LDPE (factors of 1.6 to 1.9). The implications are that proficiency testing programs may give more realistic estimates of uncertainties in chemical analysis than within-laboratory quality control programs and that these high uncertainties should be taken into account in environmental assessments. © 2024 American Chemical Society.
Files in This Item
There are no files associated with this item.
Appears in
Collections
해양과학대학 > Department of Marine Environmental Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Gi Beum photo

Kim, Gi Beum
해양과학대학 (해양환경공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE