Cited 0 time in
열전모듈과 냉각부 간 열접촉저항 변화에 따른 열전달 특성에 대한 해석적 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 고성곤 | - |
| dc.contributor.author | 박상진 | - |
| dc.contributor.author | 김태화 | - |
| dc.contributor.author | 김영욱 | - |
| dc.contributor.author | 정미진 | - |
| dc.contributor.author | 서정세 | - |
| dc.date.accessioned | 2024-03-09T02:31:56Z | - |
| dc.date.available | 2024-03-09T02:31:56Z | - |
| dc.date.issued | 2024-02 | - |
| dc.identifier.issn | 1598-6721 | - |
| dc.identifier.issn | 2288-0771 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/69859 | - |
| dc.description.abstract | Significant resources are being dedicated to developing renewable energy sources to mitigate environmental issues. One such method is thermoelectric power generation, which utilizes the thermoelectric effect. This research aims to conduct a case study to computationally analyze heat transfer. The study investigated the characteristics of the contact surface by altering the thermal contact resistance, heat source temperature, and coolant volumetric flow rate between thermoelectric modules and cooling systems. The research findings indicate that increasing the heat source temperature and coolant volumetric flow rate enhances the impact of alterations in thermal contact resistance on heat flow. In a high-temperature environment, the significance of thermal contact resistance increases. A thermal contact resistance of 10-5 m2 ‧K/W or more significantly affects the heat transfer characteristics. Furthermore, the coolant volume flow rate required for cooling the parts should be between 0.2 to 0.4 liters per minute. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계가공학회 | - |
| dc.title | 열전모듈과 냉각부 간 열접촉저항 변화에 따른 열전달 특성에 대한 해석적 연구 | - |
| dc.title.alternative | Numerical Study of Heat Transfer Characteristics Involving Thermal Contact Resistance between a Thermoelectric Module and a Cooling System | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.14775/ksmpe.2024.23.2.030 | - |
| dc.identifier.bibliographicCitation | 한국기계가공학회지, v.23, no.2, pp 30 - 37 | - |
| dc.citation.title | 한국기계가공학회지 | - |
| dc.citation.volume | 23 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 30 | - |
| dc.citation.endPage | 37 | - |
| dc.identifier.kciid | ART003052406 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Thermal Contact Resistance( ) 열접촉저항 | - |
| dc.subject.keywordAuthor | Thermoelectric Module( ) | - |
| dc.subject.keywordAuthor | Numerical Analysis 열전모듈 ( ) | - |
| dc.subject.keywordAuthor | Cooling System( ) | - |
| dc.subject.keywordAuthor | Renewable Energy( ) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.