Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Tri-axial shaking table testing of lighting support systems with pulley friction dampers and integrated dummy massesopen access

Authors
Han, Tran-VanKim, Sung ChanShin, JiukCuong, Nguyen HuuLee, Kihak
Issue Date
Mar-2024
Publisher
Elsevier
Keywords
Dummy masses; Friction damper; Seismic performance; Shaking table testing; Vibration attenuation; Wireway vibration attenuation system
Citation
Results in Engineering, v.21
Indexed
SCOPUS
ESCI
Journal Title
Results in Engineering
Volume
21
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/69478
DOI
10.1016/j.rineng.2023.101706
ISSN
2590-1230
Abstract
Investigating pulley wireway systems equipped with friction dampers as alternatives to traditional exposed raceway light fixtures, this study adheres to the ICC-ES AC156 standard and evaluates the impact of system mass and connector types on seismic behavior using shaking table tests. The key findings indicate that an increased system mass variably affects the fundamental frequency of the system, depending on the type of connectors. In terms of earthquake performance, direct connectors outperformed pole connectors in the original system configuration, and the addition of dummy masses significantly reduced seismic energy while stabilizing acceleration responses in pole connector systems. Moreover, the study underscores the critical importance of minimizing pole length in systems using pole connectors and adopting a lower mounting height in systems with direct connectors to improve seismic performance. © 2023 The Authors
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Ji Uk photo

Shin, Ji Uk
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE