Detailed Information

Cited 8 time in webofscience Cited 11 time in scopus
Metadata Downloads

Arrangement of side holes in a double J stent for high urine flow in a stented ureter

Authors
Kim, Kyung-WukKim, Hyoung-HoChoi, Young HoLee, Seung BaeBaba, YasutakaSuh, Sang-Ho
Issue Date
Feb-2020
Publisher
KOREAN SOC MECHANICAL ENGINEERS
Keywords
Hydronephrosis; Double J stent; Optimal design; Computational fluid dynamics
Citation
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, v.34, no.2, pp 949 - 954
Pages
6
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY
Volume
34
Number
2
Start Page
949
End Page
954
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/6944
DOI
10.1007/s12206-020-0144-1
ISSN
1738-494X
1976-3824
Abstract
A double J stent (DJS) is widely used as an ureteral stent these days. A DJS is composed of a shaft and proximal and distal coils, and it has multiple side holes along the stent axis. The role of side holes must be a supply of detour. Several studies on side holes have been conducted. Various parameters, such as the number of side holes, the distance between adjacent side holes, and the degree of ureteral stenosis, have been evaluated. Studies have shown that increasing the number of side holes increases the overall flow rate, but it has not presented an important role in the absence of ureteral stenosis. In the absence of ureteral stenosis, only a few proximal and distal side holes show a role of detour, and the flow of urine through a stent is negligible. Here, we examine whether urine flow through a stented ureter is maximized by removing side holes in the midshaft and increasing the number of side holes in the proximal and distal segments of the stent shaft. We establish an undulated curved ureter model and compare a stent with only proximal and distal side holes in the shaft with a stent with side holes along the entire shaft in a point of flow rates in the ureter and flow patterns around side holes. The stent with side holes along the entire shaft (16.5 mL/h) shows a higher total flow rate compared with the stent with only proximal and distal side holes in the shaft (12.7 mL/h).
Files in This Item
There are no files associated with this item.
Appears in
Collections
융합기술공과대학 > 기계소재융합공학부 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyoung Ho photo

Kim, Hyoung Ho
우주항공대학 (항공우주공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE