Clinical Experience of 1-Minute Brain MRI Using a Multicontrast EPI Sequence in a Different Scan Environmentopen access
- Authors
- Ryu, K. H.; Baek, H. J.; Skare, S.; Moon, J., I; Choi, B. H.; Park, S. E.; Ha, J. Y.; Kim, T. B.; Hwang, M. J.; Sprenger, T.
- Issue Date
- Mar-2020
- Publisher
- American Society of Neuoradiology
- Citation
- American Journal of Neuroradiology, v.41, no.3, pp 424 - 429
- Pages
- 6
- Indexed
- SCIE
SCOPUS
- Journal Title
- American Journal of Neuroradiology
- Volume
- 41
- Number
- 3
- Start Page
- 424
- End Page
- 429
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/6903
- DOI
- 10.3174/ajnr.A6427
- ISSN
- 0195-6108
1936-959X
- Abstract
- BACKGROUND AND PURPOSE: The long scan time of MR imaging is a major drawback limiting its clinical use in neuroimaging; therefore, we aimed to investigate the clinical feasibility of a 1-minute full-brain MR imaging using a multicontrast EPI sequence on a different MR imaging scanner than the ones previously reported. MATERIALS AND METHODS: We retrospectively reviewed the records of 146 patients who underwent a multicontrast EPI sequence, including T1-FLAIR, T2-FLAIR, T2WI, DWI, and T2*WI sequences. Two attending neuroradiologists assessed the image quality of each sequence to compare the multicontrast EPI sequence with routine MR imaging protocols. We used the Wilcoxon signed rank test and McNemar test to compare the 2 MR imaging protocols. RESULTS: The multicontrast EPI sequence generally showed sufficient image quality?of >2 points using a 4-point assessment scale. Regarding image quality and susceptibility artifacts, there was no significant difference between the multicontrast EPI sequence DWI and routine DWI (P?>?.05), attesting to noninferiority of the multicontrast EPI, whereas there were significant differences in the other 4 sequences between the 2 MR imaging protocols. CONCLUSIONS: The multicontrast EPI sequence showed sufficient image quality for clinical use with a shorter scan time; however, it was limited by inferior image quality and frequent susceptibility artifacts compared with routine brain MR imaging. Therefore, the multicontrast EPI sequence cannot completely replace the routine MR imaging protocol at present; however, it may be a feasible option in specific clinical situations such as screening, time-critical diseases or for use with patients prone to motion.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medicine > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.