Cited 21 time in
Clinical Experience of 1-Minute Brain MRI Using a Multicontrast EPI Sequence in a Different Scan Environment
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ryu, K. H. | - |
| dc.contributor.author | Baek, H. J. | - |
| dc.contributor.author | Skare, S. | - |
| dc.contributor.author | Moon, J., I | - |
| dc.contributor.author | Choi, B. H. | - |
| dc.contributor.author | Park, S. E. | - |
| dc.contributor.author | Ha, J. Y. | - |
| dc.contributor.author | Kim, T. B. | - |
| dc.contributor.author | Hwang, M. J. | - |
| dc.contributor.author | Sprenger, T. | - |
| dc.date.accessioned | 2022-12-26T13:02:21Z | - |
| dc.date.available | 2022-12-26T13:02:21Z | - |
| dc.date.issued | 2020-03 | - |
| dc.identifier.issn | 0195-6108 | - |
| dc.identifier.issn | 1936-959X | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/6903 | - |
| dc.description.abstract | BACKGROUND AND PURPOSE: The long scan time of MR imaging is a major drawback limiting its clinical use in neuroimaging; therefore, we aimed to investigate the clinical feasibility of a 1-minute full-brain MR imaging using a multicontrast EPI sequence on a different MR imaging scanner than the ones previously reported. MATERIALS AND METHODS: We retrospectively reviewed the records of 146 patients who underwent a multicontrast EPI sequence, including T1-FLAIR, T2-FLAIR, T2WI, DWI, and T2*WI sequences. Two attending neuroradiologists assessed the image quality of each sequence to compare the multicontrast EPI sequence with routine MR imaging protocols. We used the Wilcoxon signed rank test and McNemar test to compare the 2 MR imaging protocols. RESULTS: The multicontrast EPI sequence generally showed sufficient image quality?of >2 points using a 4-point assessment scale. Regarding image quality and susceptibility artifacts, there was no significant difference between the multicontrast EPI sequence DWI and routine DWI (P?>?.05), attesting to noninferiority of the multicontrast EPI, whereas there were significant differences in the other 4 sequences between the 2 MR imaging protocols. CONCLUSIONS: The multicontrast EPI sequence showed sufficient image quality for clinical use with a shorter scan time; however, it was limited by inferior image quality and frequent susceptibility artifacts compared with routine brain MR imaging. Therefore, the multicontrast EPI sequence cannot completely replace the routine MR imaging protocol at present; however, it may be a feasible option in specific clinical situations such as screening, time-critical diseases or for use with patients prone to motion. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Society of Neuoradiology | - |
| dc.title | Clinical Experience of 1-Minute Brain MRI Using a Multicontrast EPI Sequence in a Different Scan Environment | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.3174/ajnr.A6427 | - |
| dc.identifier.scopusid | 2-s2.0-85082097937 | - |
| dc.identifier.wosid | 000521965200015 | - |
| dc.identifier.bibliographicCitation | American Journal of Neuroradiology, v.41, no.3, pp 424 - 429 | - |
| dc.citation.title | American Journal of Neuroradiology | - |
| dc.citation.volume | 41 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 424 | - |
| dc.citation.endPage | 429 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Neurosciences & Neurology | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
| dc.relation.journalWebOfScienceCategory | Neuroimaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | RESONANCE-IMAGING PROTOCOL | - |
| dc.subject.keywordPlus | SYNTHETIC-MRI | - |
| dc.subject.keywordPlus | QUANTIFICATION | - |
| dc.subject.keywordPlus | AGREEMENT | - |
| dc.subject.keywordPlus | STROKE | - |
| dc.subject.keywordPlus | KAPPA | - |
| dc.subject.keywordPlus | FLAIR | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
