Detailed Information

Cited 3 time in webofscience Cited 2 time in scopus
Metadata Downloads

Comparative analysis between STANDARD-E Covi-FERON ELISA with pre-existing IFN-γ release assays and determination of the optimum cutoff value for assessment of T-Cell response to SARS-CoV-2open access

Authors
Jang, J.Widyasari, K.Kim, S.
Issue Date
Mar-2023
Publisher
John Wiley & Sons Inc.
Keywords
COVID-19; cutoff value; interferon-gamma; interferon-gamma release assay; kappa-index; T-cell response
Citation
Journal of Clinical Laboratory Analysis, v.37, no.6
Indexed
SCIE
SCOPUS
Journal Title
Journal of Clinical Laboratory Analysis
Volume
37
Number
6
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/59310
DOI
10.1002/jcla.24882
ISSN
0887-8013
1098-2825
Abstract
Background: Interferon-gamma (IFN-γ) release assays (IGRAs) are useful for the assessment of the T-cell response to severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2). We aimed to assess the performance of the newly developed IGRA ELISA test compared to the pre-existing assays and to validate the cutoff value in real-world conditions. Methods: We enrolled 219 participants and assessed agreement between STANDARD-E Covi-FERON ELISA with Quanti-FERON SARS-CoV-2 (QFN SARS-CoV-2), as well as with T SPOT Discovery SARS-CoV-2 based on Cohen's kappa-index. We further determined the optimal cutoff value for the Covi-FERON ELISA according to the immune response to vaccinations or infections. Results: We found a moderate agreement between Covi-FERON ELISA and QFN SARS-CoV-2 before vaccination (kappa-index = 0.71), whereas a weak agreement after the first (kappa-index = 0.40) and second vaccinations (kappa-index = 0.46). However, the analysis between Covi-FERON ELISA and T SPOT assay demonstrated a strong agreement (kappa-index >0.7). The cut-off value of the OS (original spike) marker was 0.759 IU/mL with a sensitivity of 96.3% and specificity of 78.7%, and that of the variant spike (VS) marker was 0.663 IU/mL with a sensitivity and specificity of 77.8% and 80.6%, respectively. Conclusion: The newly determined cut-off value may provide an optimum value to minimize and prevent the occurrence of false-negative or false-positive during the assessment of T-cell immune response using Covi-FERON ELISA under real-world conditions. © 2023 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sun Joo photo

Kim, Sun Joo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE